  1. S

    New Consumer Unit

    Well I thought it was a bit strange as the main switch is double pole and isolates all live conductors anyway. Only reason I could think was so that even the tails entering the Consumer Unit were isolated so the board was ALL dead (not just the circuits)
  2. S

    New Consumer Unit

    Am i right in saying that when a new consumer unit is installed on a single phase supply there should be a double pole switch between incoming companies fuse and the Consumer Unit??? Was reading the 17th edition the other day and spotted this?? Regards Ian
  3. S

    Transformers and 12v lights

    I have already got installed 12v down lighters with 1 transformer per light. The transformers are 20-60VA. I have just purchased 3W LED lamps (mr16) to replace the 20w 12v halogen lamps. When i put the LED lamps in the fitting they came on fine for about 5 mins then started to flash then went...
  4. S

    Light bulbs keep popping

    Can anybody explain why lightbulbs on a 3 head light fitting keep popping at random times? Put a new bulb in and it lasted about 2 days then another one lasted about 1 week! Any help appreciated!
  5. S

    Rccd tripping

    Thanks for the quick reply. I had a feeling that they had had a surge which caused then to fail but was wondering how these anit surge units were made and wat happened inside them to cause an earth fault. I'm just curious. And sorry for the exclamation marks I'm using my iPhone and its habbit.
  6. S

    Rccd tripping

    Hi, been to a job today and it was a funny one! The rccd was tripping! Found fault to be on down ring main! Unplugged everything and it stayed on! I then plugged in their 4 way surge protected extension bar and it tripped immediately! Nothing was plugged into the bar! So a faulty extension bar...
  7. S

    fuseboard question

    So I need to charge to do a periodic inspection before i can quote to replace in the CU?? Then do another test and inspect once the job is done?????????
  8. S

    fuseboard question

    OK Mrs smith asks for her Cu to be changed, I price to swap board, test and inspect all circuits, upgrade main earth and upgrade earthing to Gas and Water. What happens in this instance....the board has been changed and in the process of testing lighting find that theres crossed polarity on a...
  9. S

    fuseboard question

    I have my own company and we would charge around about the £300-£350 to change the CU and do a full inspect and test. Based on a 3 bed semi with garage!
  10. S

    Setting up twin Dellortos

    I have just fitted a set of twin 40s on my 1.8 pinto engine and am wondering how to set the carbs up for best running! Does anyone have any information to help me try and set them up!
  11. S

    Switch with no earth

    Yes the rest of lighting circuit is earthed, just that one switch! I was concerned of the possibility of a live conductor coming out touching the back box thus making the screws on the faceplate live!!
  12. S

    Switch with no earth

    Im replacing plastic 1g2w switches for new plastic 1g2w's. It is a metal back box in a brick wall. One of the switch boxes in the living room doesnt have an earth at the box! It is wired in double sheathed singles so its not a case of it have being cut short. The switches are plastic and they...
  13. S

    Using an earth rod to bond gas and water??

    well most dont understand! haha! I am keen to learn just dont get the time to read books!
  14. S

    Using an earth rod to bond gas and water??

    you know exactly where im coming from bernard green! Alot of commercial sparks on sites can wire from a drawing and install to a high standard but havent done design courses, therefore dont understand the reasons behind!
  15. S

    Using an earth rod to bond gas and water??

    Thanks edward! I accept everyones advice and a spark should know these things but not when my main experiance is in containment and circuit wiring! Everyone is still learning and ill now look in my books and find out what i dont understand!
  16. S

    Using an earth rod to bond gas and water??

    Yes it will be fine! Would need to upgrade to 16mm when run approaches 30-35m
  17. S

    Using an earth rod to bond gas and water??

    Yes! But just passed my 17th in June!
  18. S

    Using an earth rod to bond gas and water??

    Im Part P approved and with the ECA
  19. S

    Using an earth rod to bond gas and water??

    Anyway thanks for the advice, ill be pulling in a earth from the CU via trunking on the skirting board!!