  1. S

    PIR LIGHT not working.

    Duff info in previous post, if pir live and switched live temp joined, the light will be live no matter whether switch is on. What type of light is it?,check for damaged lamp to fitting connection(pins).
  2. S

    Sky HD magic eye

    If tv beside sky box has an analogue tuner, connect rf2 to tv aerial and scan for channel to see if rf2 is faulty, also connect up bedroom with main aerial to see if bedrooms can receive digital channels(temp remove magic eyes).
  3. S

    PIR LIGHT not working.

    More than likely the pir is goosed, you could open pir(switch off supply) disconnect live & switched live from pir and temp join them together with suitable connector, power back on and operate switch to see if the light now works. Is the new lamp known to work.
  4. S

    No earthing on dimmer module?

    Is the faceplate the dimmer module is attached to metal?, if it is there should be an earth connection on it, connect the earthwire to it. If its a plastic faceplate, there will be no earth connection as its not required, If the existing earth on module comes from back box just disconnect...
  5. S

    Most stupid comment of the day

    I got door stopped by a neighbour, she had the single insulated flex on a table lamp, dog had chewed it up , so she stripped ends, twisted a core of each together and then sellotaped the 2 joints together, asked why it blew the fuse.
  6. S

    integrated dishwasher wiring advice

    13a switch spur above - 20a flex outlet below, if fuse blew/ruptures you dont have to remove dishwasher to replace.
  7. S

    integrated dishwasher wiring advice

    Probable the reason a spur was used instead of socket is space at the back dishwasher, ie very little. Measure existing space of unit from front of carcass to face of spur, measure size of dishwasher from back to inside lip of front. would that space between the two allow for 13a plug?.
  8. S

    80mm & 85mm cut out downlights

    Were the old lights R63/R80 style. 82mm cut out http://www.screwfix.com/p/robus-adjustable-round-mains-voltage-downlight-polished-chrome-240v/53815 Eyeball fittings are big cut outs as-well, you should find different options.
  9. S

    Replacing lightswitches.

    If the previous owner did dodgy electrical work, I'd be wary of trusting them for earth continuity. Buy yourself a voltage/continuity tester or multimeter.
  10. S

    Boiler / RCD Issue

    Is there any issues with moving boiler onto non rcd circuit ?, is boiler on its own circuit ? . Get sparky to test for earth leakage current before and after boiler fired up ,with a leakage clamp meter . Also for finding leakage from any appliances.
  11. S

    Wiring for eBay room thermostat?

    What is the make and model no. of old & new stats. Upload pic of existing stats connections.
  12. S

    Electrician walked off job, need completion certificate

    Malicious installer is a bit harsh?, we only have 1 side of the dispute .
  13. S

    Wiring central heating so fire stat can select zones

    Use 2 gang switch, 2 mv in 1 of 2 way switch , 1 of the 2 mv is always connected.
  14. S

    Anybody heard of V90?

    Looking online, V90 stands for domestic installations.
  15. S

    Pir wiring confirmation

    D connection is live supply at switch, which loops to A, remove loop and connect wire B to D.
  16. S

    wiring 5 security lights

    http://www.scotland.gov.uk/Topics/Built-Environment/Building/Building-standards/publications/pubtech/th2013domcomp 6.5.2 Fixed external lighting Where fixed external lighting is installed, such as to enable safe use of external areas when natural light levels are not sufficient or for...
  17. S

    Ref Cooker Switch

    Did you check polarity?.
  18. S

    Electrician walked off job, need completion certificate

    I dont know if your getting the gist of my post, surely the labour was more than 2 days?.
  19. S

    Pir wiring confirmation

    1 gang switch - lantern wire (B) - connect to live connection at switch(D) or change 2gang 2way switch for 2gang with 1 keyswitch+1way switch available in grid or module setup.
  20. S

    Electrician walked off job, need completion certificate

    £400 (2 days labour what i charged) for a big refub and loft conversion.