  1. S

    Power Shower Broken RCD

    Looks like a mechanical issue within the Rcd mike.
  2. S

    Power Shower Broken RCD

    Sounds like the Rcd is tripping. Rcd needs to be tested in isolation, shower & lighting live & neutrals disconnected(power off), then reset Rcd.
  3. S

    Power Shower Broken RCD

    Mike your pic on page3 shows tails connected to top of RCD, look at bottom of pic you can see the neutral lead that goes to the neutral bar. Can you switch the Rcd off/on manually, can you feel the switch latch in the on position. Get the Rcd tested by an electrician.
  4. S

    marrettes / wire nuts

    Newlec (Ross electrical) sold me these over a year ago.
  5. S

    Power Shower Broken RCD

    If its a rewireable fuse(fusewire) can you remove & and see if its blown?.
  6. S

    Power Shower Broken RCD

    How is your 2 way Rcd board power supplied, Henley block or from a fuse in existing board?. I know you said he tested and current was on bottom/load side of Rcd, but he doesn`t inspire confidence to me.
  7. S

    Power Shower Broken RCD

    Get your mate to test it to see if it is faulty.
  8. S

    Power Shower Broken RCD

    No idea what he means by clean it up?. He could test it, to see if it is operating within spec, but seeing as he said there was no power on the load side off rcd(did he disconnect existing load from rcd and then try testing?) maybe its goosed, testing would confirm.
  9. S

    Wiring a Danfoss RMT230 from a Danfoss RET230NSB

    Do you have a tester to check for voltage at the stat?. Has the heating worked since your dad removed the stat from its base for papering?.
  10. S

    Electric Oven Tripping RCD - Not the heating element?

    http://www.electrolux.co.uk/Support/Troubleshooter/Trouble-shooter-other-solutions/ Searching for parts for your oven...
  11. S

    manrose humidistat playing silly buggers

    Loop in at light(with 3 existing twin & earth cables) 1 x live,neutral & earth (supply in) 1 x live,neutral & earth (supply out to next light) 1 x live, switched live & earth to switch 3 x red chock block - perm live - brown fan isolator switch - brown fan p/l 1 x black(sleeved red) -...
  12. S

    manrose humidistat playing silly buggers

    Is the fan a new install in bathroom or a replacement?. Normal wiring colours. brown - perm live black(sleeved brown) - switched live grey(sleeved blue) - neutral
  13. S

    Triton Shower Earth Problem

    If you rule out water pressure, check operating instructions that came with shower(fault finding). Looking at triton info, shower min 1bar max 10bar. Check for continuity across thermal cutout (with power off) its on top of the water tank.
  14. S

    Wiring a Danfoss RMT230 from a Danfoss RET230NSB

    The RMT230 has no light/neon built in
  15. S

    How to choose layout & number of downlights

    If i was installing downlights in a lounge, i would have each row independently switched, and dimmed if lamps/transformers used. I would fit 3 rows x 4 and if more needed fit after(warm lamps).
  16. S

    Bonding

    What happens if RCD fails and there is no supplementary bonding in place.
  17. S

    How to choose layout & number of downlights

    Chose warm lamps ,cool to bright.
  18. S

    Triton Shower Earth Problem

    Solenoid, water pressure as above turn on water.
  19. S

    How to wire in parallel motion light sensor and push button

    Push button timer will have a set time for lighting to stay on, motion sensor may have in-built time setting, they should all be wired from the same circuit, i would expect which ever has the longest time setting, to override the other, dependant on when each one detected motion or button pressed.