  1. W

    Baxi Genesis 80

    You should be looking for a filling loop that is connected from towns mains 15mm into the return 22m
  2. W

    Rough cost of wet under floor heating

    the room is 15x10 but you have not stated if that is wall to wall or unit to unit. Reason I ask is this kind of installation is not worth installing under units/appliances making the rooms heated surface area smaller and cheaper. Like agile says It's an expensive installation when a radiator...
  3. W

    Increasing Pump Head

    But it will get hot all over the surface area of the radiator and that was one of the questions that was asked. How would you get the bottom of the rad hot because that has always worked for me when balancing a system, unless their is a problem with the pipework or a build up of sludge in the...
  4. W

    Increasing Pump Head

    Ok i was a little drunk when i was trying to explain this. By closing the lock shield and opening it 360 it reduces the flow rate allowing the radiator to get hotter lower down the radiator. Depending on where the cold and hot meet depends on how much you turn the lock shield. The trv...
  5. W

    Rough cost of wet under floor heating

    Go here and it will tell you everything you need to know. There are other products on the market that will do the same job but this gives you a great answer to all of your questions http://www.hep2o.co.uk/ufh/UFH_RS_IG.pdf Here for anything else http://www.hep2o.co.uk/index.htm Hope...
  6. W

    it is ILLEGAL to sign off work from non-corgi

    I had a friend who was too busy to do his cousins boiler move and asked me to do it. I attended his property and was told that he had not moved in yet and was about 2 weeks away from moving in. When I tested the gas the drop was terrible, just like an open end. So i capped the gas off until I...
  7. W

    are lead pipes illegal?

    a lead lock will not repair lead only convert it to copper
  8. W

    combi hot water flow problem

    check that the cold water is flowing into the boiler, it may have been turned off by an isolation valve or in some cases I have found that if the filling loop has one end still open then it will not allow the hot to flow. No doubt someone will ridicule me and pass this off as nonsense but hey...
  9. W

    can any one help please

    flushing cost wise depends on what part of the uk u live. We charge £450 with the magnaclean system I would recommend you try yourself first if you feel competent enough to do so and add sentinel X400 for a couple of weeks then flush your system. Either way the boiler does not need to be...
  10. W

    Ravenheat Printed Circuit Board for a RSF 8/20 fanned Combi

    heacas in rochdale should supply that part and also parts center in stockport or oldham, PTS these 2 if not in stock usually can order it for next day or day after
  11. W

    Loud bangs coming from boiler

    just one question. Have you had it serviced in the 4 years?
  12. W

    Ideal Response Boiler won't relight!

    kath you hijacked someone elses thread. You need to ask admin to start you a new one
  13. W

    Worcester Boiler & Programmer

    sorry the 90s was just a blur for me. I misread the message also and thought that the house was a new build and therefore would not have had a boiler that is over 10 years old. As soon as I got a reply i realized that he means the rsf and i have serviced many of these along with the ideals...
  14. W

    replacing leaking hot water heater and boiler, need advice

    I would install a system boiler with a keston spa cylinder or similar as opposed to a combi.
  15. W

    are lead pipes illegal?

    If lead was ok then why would manchester council replace all lead piping for FREE. Also whenever work is done on a gas pipe we have been told that any lead has to be replaced.
  16. W

    Ventilator for round hole in glass - also spirits of salt

    Also the slate would do. But if your roofs copper get it weighed in a buy some timber. You can sleep safe at night knowing no one will have nicked it for scrap along with your lead Most of these fans are now put on a switch rather than a cord. All you need to do is phone an electrician and...
  17. W

    Worcester Boiler & Programmer

    no one will have answered because they would be wasting thier time. If you cannot follw the instructions you would not be able to follow them on here. Also i cannot recall a 28cdi. there is a 30cdi or a 28i junior
  18. W

    Keep having to use the filling loop - Microgenus 27 MFFI

    I would let your central heating get to temperature and then turn the boiler off. Open the hot tap and see if the water gets hotter as its running. If it does then your heat exchange is passing the heating circuit into the hot water chamber and your pressure would drop. Or turn off the towns...
  19. W

    Glowworm 18HXi - not again!!

    so heating engineers can make a nice profit for a minor job that you need to be corgi reg to legally repair.
  20. W

    potterton envoy boiler problems??

    Some prices have been put on here or a rough guide. http://www.diynot.com/forums/viewtopic.php?t=115422 I would try a cleaner first as its easy to administer via the header tank, could save you £300-400 pounds Sentinel X400 left in your system for couple of weeks should do the trick but...