Search results

  1. S

    Rayburn PJ Ecoflame burner

    I would suspect that you either have a clogged filter in the oil pump or water in the oil. spraggo
  2. S

    Smells in downstairs Wc

    You may be aware that the AAV is a device that normally seals the top of the soil pipe from the atmosphere. However, when you flush the toilet a vacuum is created within the soil pipe and the resulting suction causes the AAV to open and let air in to release the suction. If the AAV is faulty by...
  3. S

    boundary line

    I give up :? :?
  4. S

    boundary line

    So adverse possession CAN be claimed :?: :?:
  5. S

    boundary line

    :? :?
  6. S

    boundary line

    . Unfortunetly, if your rear fence was moved on to your land more than 12 years ago and their has been no disputing it since, then your neighbours can claim your land by adverse possession. If it was moved less than 12 years ago then your house deeds will show exactly what land you own...
  7. S

    replacing switchmaster300 with Honeywell st9400c

    Thanks for spotting my mistake Doitail, obviously it should read, connect raburn live to 3 and pump live to 4 with neutrals connected to N. But he says that he only wants to use one channel?
  8. S

    replacing switchmaster300 with Honeywell st9400c

    Wiring connections for Honeywell ST9400c are as follows:- L N 1 = HW OFF 2 = CH OFF 3 = HW ON 4 = CH ON So connect rayburn and pump to live to 4 and neutral to N
  9. S

    Luke warm water fron cylinder

    Check that the small header tank in attic is approx one third full of water, if not it is probably due to the balll valve being stuck.
  10. S

    Vaillant VCW-sine 18

    Tell your engineer to suspect the air pressure switch. Part No 05-0518
  11. S

    air admittance valve on soil pipe

    Yes, but make sure that the boxing is not air tight.
  12. S

    Recommended Hot Water Temperature

    60 will be OK with the cyl stat fitted one third up from the bottom of the cylinder
  13. S

    Heating programmer

    That is correct
  14. S

    Heating programmer

    It is used to select 10 or 16 programmes depending on whether you have a fully pumped or gravity system. Switch it to 16 if you have fully pumped.
  15. S

    problems with rayburn royal 1979 with original oil burner

    Suspect fault in oil float control, like sticking float valve needle or partial blockage in calibration needle slot. Also check that lever on thermostat pushes pin down when set to 5.
  16. S

    NO HOT WATER FROM NEWLY INSTALLED MIRA PLAY 9.5KW

    Go to:- http://www.mirashowers.co.uk/home.htm Select, support, installation guide, and select shower to download
  17. S

    help - partially cold, noisy, apparently empty rads

    And don`t forget, if you need to bleed the radiators, normally indicated by them being cold at the top, you must switch the heating OFF to do this. Then afterwards make sure you repressurise the system to 1.5 bar BEFORE you switch the heating back ON. Merry Xmas. spraggo
Back