  1. S

    Grant Combi 90 oil boiler

    It is worth mentioning that the rust was probably caused by condensation. This would happen due to low temperature water in the return pipe created by running the boiler with the thermostat turned down or the system not balanced to give a temp of 11 degree centigrade difference between flow and...
  2. S

    Being dumped on!

    I take it that you realize that, if the sewerage did back up and close this valve, that your toilet is likely to overflow when you pull the flush. :( :(
  3. S

    Syphoning problems

    If you have installed the valve correctly, arrow pointing in the direction of flow, and the outlet joints are secure and not letting water in. It indicates that the valve is not seating properly due to debris or being faulty.
  4. S

    Syphoning problems

    These are one way valves not spring loaded check valves. There is no problem submerging the brass valve in water for long periods. Why not get a copper copper 15mm compression valve and use a couple of 15mm copper tails to connect to the hose with jubilee clips. What head of water is the pump...
  5. S

    Syphoning problems

    If you had fitted the valve just above the pump as I suggested you would not now be getting these problems,
  6. S

    UFH added to y plan

    Son :!: :!: thank you old man, I`ll take that as a compliment :D :D
  7. S

    UFH added to y plan

    Son :!: :!: thank you old man, I`ll take that as a compliment :D :D
  8. S

    Type of nut

    It is known as a knurled nut try here http://www.accuratescrew.com/Nuts.aspx
  9. S

    Syphoning problems

    Install a spring loaded check valve in the pipe work just above the pump.
  10. S

    UFH added to y plan

    OK o wise one, spill the beans :mrgreen: :mrgreen:
  11. S

    gas cooker

    Spilled fat, gravey etc, on the burner in the vicinity of the thermocouple preventing the flame from heating it
  12. S

    water in toilet being syphoned out

    I think that the OP is confused and that he means that the toilet PAN is being syphoned out, in which case it would indecate that there is no open vent or Durgo valve on the soil stack.
  13. S

    UFH added to y plan

    Not a good design, one pump could pull against the other when both on. this would cuase cavitation and if it was an OV system it would cuase water to be pulled down from the expansion tank and would cause pumping over via the expansion pipe, what size are the primary flow and retun pipes?.
  14. S

    What are these??

    The aerjec if not fitted correctly,(Click on spraggo to go to my profile to see a sketched image of the right connections),hence the reason for the air in your system.
  15. AERJEC

    AERJEC

    CONNECTIONS
  16. spraggo

    spraggo

    queries
  17. S

    Do I have a Surrey Flange?

    http://www.wickes.co.uk/surrey-flange/invt/421901/
  18. S

    pressure reducing valve fitted but still got water hammer

    The rubber hose, usually supplied with the W/M will normally stop water hammer from the machine. Is this fitted?.
  19. S

    tap washers

    Try using 1/2" "Delta" tap washers