  1. SparkyNinja

    earth bonding

  2. SparkyNinja

    Guide to buying new sockets, quality

    TBH I havn't seen a guide in itself. Your best option is probably to ask the elctricians here what brand they prefer to use. Kinda like doing your own online survey. I myself prefer MK. It's always the brand I go to first if cost isn't too important. You can contact manufacturers directly...
  3. SparkyNinja

    Where do I put all the wires

    Did you study the connections prior to disconnecting the original fitting? It sounds likely that the individual red will be the switch line, however this cannot be guaranteed. If it is, then the two reds in the twin and CPC cable will need to be connected in their own connector that is likely...
  4. SparkyNinja

    watts and amps

    Incorrect
  5. SparkyNinja

    earth bonding

  6. SparkyNinja

    earth bonding

    Are you carrying out any electrical work in the bathroom?
  7. SparkyNinja

    500w flood

    I tend to normally explain to the client regarding L1B however if they insist then just get a written waiver on behalf of any of your design.
  8. SparkyNinja

    Questions

    where all metal is bonded together but not to earth, in essence a faraday cage.
  9. SparkyNinja

    Eastern european installation.

    Or not :roll:
  10. SparkyNinja

    Eastern european installation.

    Maybe this topic shouldn't be discussed any further. Or divert the attention to the fact that it is likely the workers consider themselves competent but havn't retrained since coming here? However I don't know if this work is to standard from where they originally trained,. assuming they did.
  11. SparkyNinja

    Wiring a shower to a generator

    It will all depend on the condition of the shower, the condition of the generator and the siting of the generator. Only when an electrician see these things will they be able to judge how much their balls will ache, and yours.
  12. SparkyNinja

    Need to Bond Bathroom

    Well to put it more acuratley: 701.415.2 it states (paraphrased) No supp bonding required in bathroom if i) disconnection times met ii) RCD protection to all circuits iii) all extraneous conductive parts of the location (ie the bathroom) are effectively connected to main equipot...
  13. SparkyNinja

    Need to Bond Bathroom

    Can you be a little more specific. Has an electrician already carried out testing in the bathroom? In what way did they say 1666ohms?
  14. SparkyNinja

    Fire alarm systems

    Well it's an old village pub, and the previous landlord allowed smoking on a 'lock in'. So the regulars may encourage it to the new landlord. Just an observation of mine really. I'd rather have heat alarms installed instead of them removing them if they go off.
  15. SparkyNinja

    minor works certs

    any
  16. SparkyNinja

    minor works certs

    but you don't put '17th' on the cert.
  17. SparkyNinja

    NICEIC DI

    Doubt the DNO were involved, as the seal dissapears. How can someone consider themselves competent to fill in these certs when they do this kinda thing.
  18. SparkyNinja

    Fire alarm systems

    Well I provisionally have planned a 4 zone system. With high-heat detector in kitchen, 2 x heat detector in bar/dining area and 2 smokes (1 upstairs and 1 in chiller/cellar area. With a call point at the kitchen escape and back door.
  19. SparkyNinja

    Fire alarm systems

    Digging up this old thread, but it's on topic. I am putting an estimate together for a full public house refurb. It currently has no emergency lighting and no smoke/fire alarms. So my question is will it need a whole new fire alarm system? Instead of interlinked smokes? I am under the...
  20. SparkyNinja

    Square D - 3871 Type QO-E max ZS values anyone?

    Got this follow up from schneider today: You guys have really come up trumps for me. :D Cheers.