  1. SparkyNinja

    new rose light

    This kinda explains it http://www.diynot.com/wiki/electrics:lighting:problems:blackswlive
  2. SparkyNinja

    new rose light

    Well it'll have to come off somehow. When this happens to me I wedge a screwdriver through the cable entry point on the back of the rose and with a twist can lock it in position. Then I have the leverage to be able to force the rose off. If you are gonna try this, turn the supply off first...
  3. SparkyNinja

    lighting.

    But you still want to be able to switch them independently? Correct??
  4. SparkyNinja

    lighting.

    Well than the simplest method would be to divert the existing switch lines to their new position, if you have to do a joint connection then make sure it's accessible and done accordingly. Ideally, if you can gain access to both light positions and the new switch position from above, then...
  5. SparkyNinja

    new rose light

    Is the only work you have done been the light fitting, no switches or anything else? Was everything working fine beforehand? If the fitting was securely fixed then then the rose should come off with some pressure. If you can get the rose off and then post a picture of the connections then we...
  6. SparkyNinja

    lighting.

    Is the room currently undergoing refurbishment? How close together are the lights? Are they on the same circuit? - does the one MCB at the fuseboard isolate both lights? Do you have access to above the ceiling?
  7. SparkyNinja

    earth loop reading

    I asked this question because if you are getting a Zs of 4.56 WITHIN the consumer unit as it sounds, then it is in there that the problem lies and the internal connections should be checked as GreenElectrics has suggested.
  8. SparkyNinja

    How hard is it to become Part P certified?

    As do the NICEIC, but only the proposed QS. How about calling the LABC before hand?
  9. SparkyNinja

    earth loop reading

    what were the R1+R2 readings like? how about the end to end ones? r1, rn etc?
  10. SparkyNinja

    earth loop reading

    Could you explain this a little easier? What terminations did you connect to?
  11. SparkyNinja

    To earth a rental or not.

    Taken from here My advice would be to express your concern to the landlord. Estate agencies are utterly useless at the moment with regards to electrical saftey and 'surveys' (hopefully in the coming years new legal requirements will be inforced). If you get nothing back then it may...
  12. SparkyNinja

    Rewire of house - currently vacant.

    You wanna seek reference's then. Sometimes the lower price and quality of work don't go well together.
  13. SparkyNinja

    Rewire of house - currently vacant.

    Yeah, ideally one with a cover to protect from impact.
  14. SparkyNinja

    Outside socket

    Is it possible to install a fcu at the position on the ring where the supply to outside comes from?
  15. SparkyNinja

    Rewire of house - currently vacant.

    You need to get other quotations in for comparison. I do council rewires with a minimal list like that and I charge £2500, inluding all the bonding, certs notification etc. If the property is vacant then the price should definatley compensate for that. More information is needed to be...
  16. SparkyNinja

    Washing machine keeps tripping the fuse

    Initially it sounds like it could be an overload on the circuit, particularly if it is the higher demanding 60 degree wash only that is causing this, however, as explained, more info is needed... Arn't we all supposed to try to wash at 30 now anyways :wink:
  17. SparkyNinja

    is this report fair

    Well if it's something stated on the report then the sparky would have contributed it as evidence? Well I do anyway :cry:
  18. SparkyNinja

    is this report fair

    Was an illustration of the adiabatic equation included to illustrate this?
  19. SparkyNinja

    Adding a spur from immesion heater wiring

    Depends on what it is for and on the existing condition of the installation.
  20. SparkyNinja

    New Consummer unit with one rcd that won't set

    Have you done a continuity test across neutral and cpc on the suspect circuits? Disconnecting the neutrals from the bar first of course?