  1. W

    Glow-Worm Feulsaver MKII Boiler Clicking Off

    Cutting out to safety you need an engineer to fit a part where you can't go into
  2. W

    Cavitation in honeywell 3 port valve V4073A

    Best place for pump is on flow with cold feed & expansion close coupled next to it. You don't have self priming cylinder do you as it is unusual for pump to be on return
  3. W

    question about Ideal boiler

    Depends on system type but more than likely possible
  4. W

    Problem wth the good old Icos M3080 (not firing up)

    Has burner been removed to check if earth pin kit has been fitted? If this is missing it can cause flashing l-f also insulation boards may have dropped down which will cause the combustion box to burn out
  5. W

    saunier duval sd620f

    probably thermister i can't remember offhand whether it is the purple spot or the orange spot but it must surely have seen better days & be due replacement
  6. W

    Help! Can't get boiler on and dad on holiday!

    It may have an immersion back up which you can use till parents get home. Also make sure the fused spur is switched on as you may have inadvertantly switched it off. If all else fails why not contact a neighbour as they will probably have same system
  7. W

    Adding Cylinder Thermostat to Gravity Hot Water

    Can you afford fuel bills with a boiler running at approx 55% efficiency the quicker you change it the more you will save
  8. W

    No Hot Water circulation

    First thing to do is remove all air from system especially the dhw flow pipe (there should be a bleed cap to loosen)
  9. W

    ICOS HE15, HE18, HE24

    There has been a safety issue regarding insulation boards dropping down which could cause l/f fault get landlord to call in a htg eng who can diagnose faults on boilers
  10. W

    HELP !! Quoted Ideal Isar 35HE. Please help ???

    I would personally recommend a 28kw vaillant but if you have very high water pressure i would suggest fitting a pressure reducing valve to protect it especially the plate heat ex
  11. W

    Installing Replacement Radiator

    The plugs are there so when it is painted the paint doesn't get on the threads so the plugs tend to stick fast maybe a bit more force with a bigger screwdriver will work
  12. W

    Vaillant boiler keeps switching on and off by itself

    Has it got warmstart switched on (depending on model) to turn off move dhw selector knob to min for a couple of seconds then restore back to original position if you want warmstart back on turn same knob to max for a couple of seconds then move back to original position
  13. W

    Vokera 20-80 R S Flowmatic - I need a new microswitch

    Easy to fit if it is the switch that is faulty & not the diaphragm which will have become stretched vokera part nos are switch 4148 diaphragm 0226
  14. W

    Radiators heat up when hot water is selected

    A possible cause is seized mechanically 3 port valve or an electrical fault on 3 port valve. To see if it is electrical turn off fused spur for a minute or so then turn it back on to see if it works (it may do it again though when you have htg only next time)
  15. W

    Water escaping from WC pan

    Must take a long time for a heavy dump to go down are you sure it ain't blocked?
  16. W

    boiler flue

    Try phoning vaillant to see if anything is available
  17. W

    Microbore to a single rad

    Probably wont give out 2.5kw of heat though
  18. W

    worchester boiler kettling or boiling at the boiler

    Has system been flushed & cleaned properly & was blr fitted before being flushed. Was reason for flush noisy boiler if so i would be suspecting heat exchanger reqd
  19. W

    baxi back boiler

    Also if you change complete valve the nuts might be a different thread so make sure you will be able to remove the olives