  1. W

    Grundfos pump not working, heating only a couple of rads.

    Could be air in pump is there water in the header tank?
  2. W

    Central Heating Technical Question

    Could be a blockage in pipework or not piped up correctly. Try closing both valves then remove rad & open each valve in turn to check flow of water (into a container of course). If the flow is ok then pipes could be transposed somewhere
  3. W

    air relief hole on closure plate

    The main purpose of the air relief opening is to dilute flue products
  4. W

    flame fail on combi boiler

    How can anybody help without knowing exact make & model etc also has it being looked at recently
  5. W

    Spare parts for a Vokera 20-80RS Flowmatic

    Won't be bg as they stock many parts for boilers over 30 years old
  6. W

    How to fit a room thermostat to a Ferroli Combi boiler

    Why not consider changing the existing wired digital timer to a programmable room stat
  7. W

    Is Microbore bad?

    Large rads don't like microbore as they dont always get flow of water needed
  8. W

    Potterton Suprima & PCB & Powerflush!

    Lately i have changed quite a few gas valves on suprimas especially if there is 911 stamped on the solenoid (black plastic)
  9. W

    Ravenheat Boiler

    It is not a pressure valve but an auto air vent. Is the pump running if so you may have circulation problems
  10. W

    CH not working - clunking

    Not familiar but if it has a twin pass heat ex then i would be suspecting pump seized or burnt out
  11. W

    Anyone had experience of Repressurising an Expansion Vessel?

    It is quite possible that the connection from the expansion vessel to the boiler is blocked & the reason it has started going to 3 bar is before you bled the rad it was acting as an expansion vessel. You can fit a remote vessel anywhere on system but don't just stand it on it's base as you will...
  12. W

    tHORN FIRES/BACK BOILER

    STOP SHOUTING Most likely i would suggest a combi with a poerflush & change rad valves etc
  13. W

    information needed on replacement boiler

    Before deciding which way to go thoroughly check condition of cylinder for leaks especially where the flow & return connections are as changing this would add extra cost
  14. W

    ideal isar m30100 electrical fault ?

    I would chuck it in a skip
  15. W

    bosch 28CDi water valve & pressure

    Pull off the grey knob & try to gently turn the white spindle with a pair of pliers. If this works you will just need a new knob if not you will need a charging link assy which can be tricky as they have being modified
  16. W

    Glow worm fuel saver F- mother board

    Does fuse blow straight away or does fan run to full speed if it is the former then it is likely that the fan is blowing the fuse
  17. W

    Glowworm Compact 80p - System trips out when CH is on

    There is a black plastic tool attached to boiler to downrate pcb potentiometer when on htg mode it will probably be set @ max (about 13mb i think) & should be approx 8mb but will need a pro to set it
  18. W

    primatic thrmostat removal

    Do you mean your back up immersion has failed? if so does it matter as you will be using your c/htg boiler anyway.
  19. W

    Vokera Combi boiler - Please help

    While you are @ boiler with hot tap running put your hand on the filling lever (used to put water in boiler) as soon as burner goes out turn from 12:00 position to 09:00 position while observing temp display. The display stops reading dhw temp & reads blr temp if it shows around 80 degrees the...