    Fixing a Lead Pipe

    Has everybody forgotten tallow & a gimlet?
  2. W

    Automatic Bypass valve or not

    Could be one of the end switches is faulty as boiler shouldn't fire without one of valves being fully open. Assuming it is wired up correctly
  3. W

    Oven gas pipework

    An oven may also be connected via an 8mm or 15mm rigid connection
  4. W

    FUSE KEEPS BLOWN ON MY BAXI 80 /105 COMBI

    Why not just swap the head (remove the 4 allen keys & it will come apart with a bit of coaxing)
  5. W

    lead to copper

    Also against water by-laws to solder water lead
  6. W

    CH Layout Question

    Why would you even consider a biasi
  7. W

    GlowWorm Swiftflow 100 - dim and flashing MAINS light

    Is pump running also fan on high speed
  8. W

    FUSE KEEPS BLOWN ON MY BAXI 80 /105 COMBI

    Probably pump blowing fuses try disconnecting live to pump & see if it carries on blowing fuses
  9. W

    Vokera Excell 80SP

    Oops made a buggar of that Will i agree with tony that fan failed but disagree that it is unusual. I carry one on my stock & generally change one every 2 weeks or so. But that may be because we have a lot of vokeras thup north with our cloth caps & whippets
  10. W

    Heating comes on when running hot water?

    Definetly diverter valve you will probably have one of the aerlier ones (around 5-6 years old) with the small holes drilled into the body
  11. W

    DHW not kicking boiler into life

    Have you considered that the kitchen tap may be faulty does it only dribble out (you will need approx 9 litres pre min which is a litre jug in about 6 secs)
  12. W

    Gas Supply to house!

    Incorrect transco are responsible to reconnect internal supply if they decide to move meter
  13. W

    no hot water vokera linea combi

    Run hot tap & observe temp on display (it reads dhw temp) as soon as blr shuts down then immediately turn isolating/filling valve from 12:00 position to 06:00 position which stops water flowing. If temp display goes up to about 82 degrees then your plate heat ex is blocked probably with magnetite
  14. W

    Glow-worm space saver 38

    Is you cylinder primatic (it may say on it self priming)
  15. W

    ravenheat rsf 820/20

    Diverter valve reqd but you would probably be better off spending money on new vaillant or worcester
  16. W

    Permanent radiator removal

    Snatching it is possible but i wouldn't risk it unless maybe under floor better to bung it or drain it
  17. W

    Does position of CH pump matter?

    If you only have a cold feed to cylinder (22mm) then you may have a sealed system do you hav a small c/htg header tank in loft?
  18. W

    vaillant fan

    Try b.g. they will do a fixed price repair (parts & labour) for about £150
  19. W

    Does position of CH pump matter?

    If you move pump then you must also move the cold feed & expansion pipes & have no valves from expansion pipe