Search results

  1. M

    Hot water, but no heating on a combi boiler!?!?!

    boiler service wont cure this problem mate !! although may help other parts and boiler life span ! have been to a few like this the divertor vlve was stuck for a few days, by the time I got back to fit part started working again.....
  2. M

    Hot water, but no heating on a combi boiler!?!?!

    consider the wax capsule in the divertor valve is the boiler fires for a few seconds periodically... combi 80 's are Puma80e's without a few parts like water pressure switch and c/h and h/w temp selectors.... 3 most common faults with these boilers ive found 1. pcb 2. diverter valve...
  3. M

    which circulation pump is best ? opinions please.

    personally think you get what you pay for but also depends on how clean systems are etc... I normally go for grundfos or myson's but if changing a head I use ideal universal heads !!
  4. M

    IDEAL ISAR HELP !!

    gonna go for the pcb mate as the valve is powered from here and if the valve was intermitting on/off and changed that then more likely the pcb... seen a few reports on suspect pcb's with older ones just dont know the symptons.... if that dont cure it I'll be taking it out and old one back...
  5. M

    IDEAL ISAR HELP !!

    wheres all the isar experts ?? first job on a friday gonna drive me mental or new pcb might just be used !!
  6. M

    Potterton puma 80. doing me nut in now

    with the c/h working fine id normally discount the DV !! as the rest position is DHW so unlikely in this event as he is getting heat and hw
  7. M

    Potterton puma 80. doing me nut in now

    when you look at the pcb, is the red led still on when when the water stops running ?? try running water, closing off then checking the led, if its still on then the flow switch is still made.. another thing to check is the frost stat...
  8. M

    IDEAL ISAR HELP !!

    to be honest the warranty aint the issue really as its been handed over to our company now but did think it should ahve 2 years therefore we shouldnt be fixing as this has been an ongoing problem tenant has advised... the last time I was at the boiler I could manually make the valve and it...
  9. M

    hot water system whining noise

    sounds like a bottle of descaler may be required !!
  10. M

    IDEAL ISAR HELP !!

    the thermister was fine mate as I said the problem last time was the valve wouldnt power and reached temp on the thermister and cut off so i replaced the valve head even though when I returned it was working ok.. the fault is intermitting but as there is demand and the valve isnt powering over...
  11. M

    IDEAL ISAR HELP !!

    yip, the demand comes on at the boiler display when calling !!
  12. M

    IDEAL ISAR HELP !!

    the valve itself seems ok.. already changed the head as it wouldnt power when calling for heat ! it makes manually ok when pusing the slider... not been back to this one yet and no doubt when I get there it will be ok again !!
  13. M

    IS THIS LEGAL

    isnt that a NCS ??
  14. M

    IDEAL ISAR HELP !!

    weve just taken over the maintenance, so presume around 1 year ago mate !! apparently came out of warranty on feb ! although i thought they had a standard 2 year warranty ???
  15. M

    IDEAL ISAR HELP !!

    Guys !! was at a job this week, no C/H on an ideal isar.. found power going to the divertor valve but it would not operate so ordered a new divertor valve head... when I arrived to fit the new part the boiler was operational again and heating working fine... anyway changed the valve and...
  16. M

    potterton 80 e lockout

    sticking microswitches on the dhw flow switch are very common with this boiler and the mentioned fault....if the red led is on the pcb board and no call for h/w then thats your likely prob, remove the switch and grease or spray with wd40 normally works..!! could be other things too but id...
  17. M

    SUPRIMA 30 BLOWING PCB FUSE

    yeah !!! was showing 0.8 ohms on multimeter.... just thrustrated last night I ran out of fuses and didnt have it handy, didnt want to look stupid and not have him heating for another night ,had it not been the pump... I should have went straight to in first tho ! but sometime nature of the...
  18. M

    SUPRIMA 30 BLOWING PCB FUSE

    guys. just to let you all know IT WAS THE PUMP thi time.. cheers...
  19. M

    SUPRIMA 30 BLOWING PCB FUSE

    chris, will keep that in mind mate if the pump aint the problem... had I had more fuses or my mulitmeter I would have found it easy enough as really didnt have much else to go for... dont think its a leakage of current to earth I would expect the mains electricity breaker to trip which in...
  20. M

    SUPRIMA 30 BLOWING PCB FUSE

    sounds good to me too, normally see the spur fuse blow on a lot of boilers when this happens and not the actual board internal fuse but the pump is direct via the pcb on these just like a combi.... hopefully tomorrow its an easy fix and is the pump.. really gotta be as its the only other...
Back