    SUPRIMA 30 BLOWING PCB FUSE

    Guys... I dont have my multimeter or fuses handy tonight when called to a mates house , suprima 30 s plan system , no lights on.. checked pcb and fuse had blown, had 1 x 3amp quick blow in my box so retried but disconnected GV and Fan, turned the boiler control knob to 0 no controls calling...
  2. M

    Girl in trouble ....Potterton 80e not working

    THE PUMA 80E DOESNT HAVE A PILOT ??????? THE PUMA 80 DOES !!!
  3. M

    Pootterton Lynx 2 combi problem

    agree on these points also, if neglected over 12 years (which hasnt been confirmed ?) then the repairs could snowball and could cost a fortune, im sure the pcb is around £175 for these alone which would be the next problem i'd look at if it wasnt sensing the flame and the electrode and...
  4. M

    Potterton Puma 80: CH ok but hot water only works when CH on

    If the boiler lights when no demand for c/h or h/w then you may find the DHW flow switch is staying on ... seen this on loads
  5. M

    Potterton Puma 80: CH ok but hot water only works when CH on

    I'll answer it NO NO NO !! Regardless of it only being the water section you are still inside the boiler. rule 26/9 should be carried out after any repair and as you are not CORGI then NO !! Pay the money and get it done right !!
  6. M

    gas leak - within limits?

    personally wouldnt leave any leak myself even if within tolerences..
  7. M

    Pootterton Lynx 2 combi problem

    got to agree doesnt sound like the gas valve either in my view and I work on a lot of lynx's !! first thing Id look at is the flame sensing electrode !
  8. M

    Bosch Wocester 28Si pressure gauage keeps rising

    you may find the expansion vessel has lost its charge therefore full of water and little or no air. If the system pressure is only rising during operation Id be inclined to check this out, failing that you may have a blockage
  9. M

    potterton 80 all works until h/w is turned on then trips

    could just be the micro switch sticking !!
  10. M

    POOR HEAT AT RADS

    THE JUNCTION BOX IS A DANFOSS BEM4000 !!! Dont know anything about thse but appears to be some kind of circuit board ??????????? could this be causing my problems ??
  11. M

    POOR HEAT AT RADS

    Advise please.... My mate has an old BAXI FIRE/BBU and over the last couple of months the downstairs rads werent heating too good. Went had a look and thought symptoms of a sludged up system, anyway added sludge remover and returned 4 weeks later and drained, when I drained the water was...
  12. M

    leaking boiler

    REFILL and test... If the leak is the heat enchanger then replace. The leak must be coming from the sealed system part for the pressure to drop as the DHW draw off is not sealed in the system and if it were leaking on this part then the pressure would not drop. If however the leak is coming...
  13. M

    POTTERTON LYNX 2 PROBLEM

    Tony... thanks... will update when i solve issue which im now 100% its a bloackage
  14. M

    POTTERTON LYNX 2 PROBLEM

    thats what I thought mate... The return isolation valve is ok though as the filling loop is underneath and i removed the flowswith and opened to see the flow and it was ok, which leaves the only the flow isolation valve although i think this is ok as it hasnt been touched .... a blockage...
  15. M

    POTTERTON LYNX 2 PROBLEM

    Tony ignore the wax capsule bit, this is not the problem as you know it doesnt have one... I didnt say it had, someoent else wrongly thought this was the problem, read my first post on this mate for the problem..
  16. M

    POTTERTON LYNX 2 PROBLEM

    its a puma your thinking off mate.. Thanks anyway
  17. M

    POTTERTON LYNX 2 PROBLEM

    I can assure you the lynx 2 does not have a wax capsule ...
  18. M

    POTTERTON LYNX 2 PROBLEM

    not on a lynx 2 mate......... :!:
  19. M

    Water shooting out of over flow

    sounds like either 1. a faulty pump causing to overheat and blow off or 2. no air in the expansion vessel, no room for expansion of hot water and causing system to rise in pressure and blow off, if its this you will be constantly topping up water pressure in your sytem second 1 only if a...
  20. M

    Lynx fault.

    Am I reading this right ??? it only worked with the NEW FLOW SENSOR AND WIRES ?? Not wires or NEW FLOW SENSOR seperately ??? Strange if correct.....