    Why would i replace Hot water cylinder ?

    namsag,i have worked and changed hundreds off warm air units and cylinders and they have all been direct cylinders. :?
  2. A

    Why would i replace Hot water cylinder ?

    it would be a direct cylinder not an indirect cylinder if you were to install one. :shock:
  3. A

    Boiler pressure

    THE VALVES ON THE FILLING LOOP,TAKE THE LOOP OFF THE VALVES AND MAKE SURE THEIR NOT PASSING.
  4. A

    Boiler pressure

    is the filling loop turned completely off also make sure the valves are not passing.
  5. A

    Boiler pressure

    does the pressure go up quickly if so sounds like your expansion vessel.
  6. A

    baxi bermuda 401 back boiler problem

    there are three wires going to the gas valve one an earth and the other two should have 240v going to them,these wires are ussually concealed under a plastic cover on the gas valve,just check that their is 240v going to them if their is and the grey knob is fully out and it still is not working...
  7. A

    One radiator not heating up after system drain down

    try turning all the other rads off and see if this pushes it through.
  8. A

    baxi bermuda 401 back boiler problem

    have you got 240v at gas valve
  9. A

    heating

    I GOT HOLD OF INSTRUCTION MANUAL OF THE WEB AND WAS ABLE TO SET CORRECT MIN AND MAX GAS PRESSURES.THIS SORTED THE PROBLEM CHEER CHRIS R. :D [/i][/b]
  10. A

    heating

    hi i have got a problem with a ferroli falcon i was asked to look at it by a landlord me being about the 5th engineer.the problem was the boiler was going through its sequences on hot water fan,aps,ignition but no flame,so i checked the gas valve and found it to be faulty and renewed it.on doing...