  1. J

    Texecom Prem 48

    I dont understand what question your asking Alarm? This is a question about Prem 48's and all Prems come with the locked by timer enable, its not a thing that was enabled by default on a grade basis as the new Galaxy panels don't have it switched on.
  2. J

    Alarm repair help

    I was told you could mix and match on panels that were designed for iD+, but the panels that were designed for old iD wouldn't take the iD+. So basically: Old panels = old chips New panels = old and new chips mixed Ofc old chips shouldn't be installed to new standards etc.
  3. J

    Texecom Prem 48

    As standard premiers come setup to force you top use a TAG to unset the system, as a result of this the panel wont accept codes while the system is unsetting. This can be switched off for each user added on the system. In wintex. Uploaded with ImageShack.us Using the keypad its again...
  4. J

    honeywell keypad

    Something doesnt look right there. I think you have your black and white crossed over, but the labels aren't very clear tbh, bit too ambiguous. Dont recognise the labels but if I had to plump for an educated guess I would go as follows. ST-, yellow goes to STROBE- R-, white goes to B-...
  5. J

    Texecom Prem 48

    Just a little tip, as default the panel will stop you using a code to unset the system until AFTER the entry timer has run out, to disable it you need to switch off the 'lock by timer' bit of each code by pressing 0 on that section. Not explained well but will become clearer when you cant...
  6. J

    Texecom Prem 48

    Right hand side of the PCB is the Auxillary tamper, there's 2 terminals which you can either link out with a bit of wire, or you can switch it off via programming, I 'think' its one one the things you can switch off in Global options > Monitor Hardware.[/i]
  7. J

    Texecom Prem 48

    If your installing it for the first time I'll gues there will be faults on it as not everything will be wired and connected when you power up (best way to do it), so you wont clear the system alerts just yet. However it what your doing with the 1+menu, 2+menu just displays the customer help...
  8. J

    Gardtec 500 early installation instructions

    Which is exactly why I posted that comment, I asked the guy to see if this version WAS any better or not and to post on here if so. Why do you feel the need to troll with such posts?
  9. J

    Gardtec 500 early installation instructions

    It may well be the exact same copy as above but its legible enough to use I believe. Do let us know.
  10. J

    Gardtec 500 early installation instructions

    Shout if you need a fairly decent readable pdf copy, got one thats decent enough to read.
  11. J

    Galaxy G2: Installing the RF & Ethernet Addons & Res

    Does the G2 have the # function to view zone resistance like the G3's? (dont use G2's sorry) Go back into option 21, browse to your chosen zone and press the # key, it may show you the actual resistance of the zone (usually 1000ohm closed, 2000ohm when open), but may help decide if you have...