Search results

  1. N

    Planning consent and time before starting work.??

    Thanks Fellas . I think I can class it as started ,so I will phone them I think and see if they can come out and discuss what I want to do . Regards Rob.
  2. N

    Planning consent and time before starting work.??

    Thanks fellas ,I thought 5 yrs to start your plans but once started I am thinking it needs to be completed in 3 yrs . Anybody confirm this for me please . Thanks. Rob.
  3. N

    Damp corner in room

    I had something similar .Again bungalow,extension at front which was my daughters bedroom .Damp patch in corner ,mouldy niff in there .Found it to be a leaky flat roof ,that was leaking at the edge and dropping water into the cavity . Replaced the roof which was rotten as hell and looked as...
  4. N

    Planning consent and time before starting work.??

    Hi Good evening, In March 06 I was given planning permission to build two bedrooms in my loft space .At the time I was knocking dining room into kitchen area to make one room and a Rsj was put in where the wall was taken down between the two rooms .This was all on the plans I had drawn up...
  5. N

    Planning consent and time before starting work.??

    Hi Good evening, In March 06 I was given planning permission to build two bedrooms in my loft space .At the time I was knocking dining room into kitchen area to make one room and a Rsj was put in where the wall was taken down between the two rooms .This was all on the plans I had drawn up...
  6. N

    Icon Extractor Fan

    Hell ,Im losing the plot now. Junction box to first light L and N and earth I think ,without taking the little box apart on the individual light .Then out of the connection box on light comes another L and N and earth wire to next light and so on .So in effect twin and earth in ,then a twin and...
  7. N

    Icon Extractor Fan

    Thanks for the replies fellas . If I go back to the beginning ,the power supply for the fan is taken off the lights in the bathroom ceiling .8 spots joined together in a loop if you like ,wire into one ,out into the next and so on ,both ends of loop back into junction box so if one bulb fails...
  8. N

    Icon Extractor Fan

    Delivery guy turns up at my door today with a new extractor for me .Still not heard any response from allaboutelectrics ,but fair play to them they sent a replacement . Another question , if the blue wire has become live and red neutral in a mix up somewhere and I wired the fan in this way...
  9. N

    Icon Extractor Fan

    Thanks sparky ,thats what I was thinking .Trouble is I cant get hold of the supplier now !!!
  10. N

    Icon Extractor Fan

    Further to this I tried to ring the helpline on the fan and it went to someones answer phone who has not got back to me !! I also emailed the people I bought it from Online .Allaboutelectrics.Again no reply and no telephone number for them .Anyone else dealt with Allaboutelectrics . Regards...
  11. N

    Icon Extractor Fan

    Unfortuanately I dont have a tester RFL .I wouldnt know what to do with one either to be honest . If I did get one what would I be looking for ?Is it complicated ? Thanks for the response .
  12. N

    Icon Extractor Fan

    RF Lighting, it is ceiling mounted and has only been in since about Oct 08. 3.5 months thats all . No wires seem to be loose or anything .
  13. N

    Icon Extractor Fan

    Hi Good evening all, I read on here about Icon 30 extractor fans ,so i fitted one in the bathroom .I got the humidity module with it and put it on the lighting circuit ,so it comes on when the bathroom begins to get steamy .(oooh er !!) However the other night it started making strange .It...
  14. N

    Flourescent strip light

    Sounding board ??? You have lost me there fella .
  15. N

    Flourescent strip light

    Thanks ban-all-sheds. So am i right in saying HF are flicker free basically as well as more efficient/economical .? We only go into utility now and then for washer/dryer etc so i may as well go for the cheaper option,as it is not on much at all . Thanks Again . Regards Rob.
  16. N

    Flourescent strip light

    Hi Good morning . Quick question. Im replacing an old 6ft flourescent strip light in my utility room ,with same or similar type . Looking at the screw*** catologue i see some are switch start circuit and a others are described as High Frequency .High frequency one being about 30 per cent...
  17. N

    Alarm for bungalow

    ok will do Breezer . Ta
  18. N

    Alarm for bungalow

    I stand corrected .Contacts . Radio ???
  19. N

    Alarm for bungalow

    Hi ,just a quick question. Live in a bungalow and it has no alarm at moment. What type of system would I need .me the wife and two kids .Entrance to a hallway,which leads to kitchen then living room .Bedrooms off the hall and toilet off the hall .There is an upstairs also . Now i am thinking...
  20. N

    Refix ridge tiles-repoint

    Thanks Chappers for the info .
Back
Top