Search results

  1. M

    Pilot Light Going Out

    From what you`ve written describing the fault,coupled with the smell,I would say it is in dire need of a service. Call in a Gas Safe Registered Engineer and get a battery operated Carbon Monoxide detector and fit it at about head height just outside the cupboard.
  2. M

    Stoves Gas Oven not working (Flame not increasing)

    99% of the time it`s the F.S.D,you will need a gas safe engineer to look at it.
  3. M

    boiler pilot light going out

    No one here will tell you what the problem is,as you`ve pretty much proved you can`t be trusted around gas appliances and you are a danger to your mother. Get a Gas Safe Registered Engineer in to service it.
  4. M

    Cannon Cooker problem

    People. If your oven burner flame stays low,it is almost certainly either the F.S.D.that is faulty or the burner is choked where the F.S.D. probe passes over the burner. If your oven burner flame stays high and burns everything it is almost certainly either the Thermostat which is faulty or...
  5. M

    Flue opening

    Before doing anything,get the chimney swept and have a smoke test carried out.You don`t want to get the fireplace altered only to find the chimney is faulty.
  6. M

    Potterton 10 16 MK2F suddenly stopped working

    If it`s the netaheat I`m thinking of,it could be something as simple as a choked pilot injector.Did the engineer you had round actually do anything,like remove the casing and have a root around? If it`s not that it will be very hard to get any parts for it and your best option would be a new...
  7. M

    Rangemaster Leisure 110

    This gap is to allow enough air in for the gas to combust properly.
  8. M

    Gas flame not high

    90% of the time this problem is the FSD,not all FSDs shut off the supply,most reduce it to a small bypass rate and when they fail it stays at the low rate. You need a Gas safe Engineer with cooker qualifications.
  9. M

    which new boiler?

    If you`re on a limited budget,replace like for like.Get a new System boiler (not a combi)make sure to get one that can be tank fed.Get the plumber to put a cleanser then inhibitor in the system.This should be the cheapest option with the least upheaval.
  10. M

    PROBLEM WITH GLOW-WORM FUEL SAVER F BOILER

    Call Gas Safe and get some phone numbers of registered engineers near you. Your husband has already put your family at risk by installing a fan himself(which involves removing the casing). Most engineers on this site could tell you the most probable cause of the fault,but won`t,because if...
  11. M

    Stoves Double Gas Oven

    Get a Gas Safe Registered engineer out(with cooker qualifications)cookers can be very difficult to dismantle and put back together even for an experienced engineer.
  12. M

    GAS PILOT LIGHT

    No they don`t. Was the bill an estimate if so they will be basing it on your when your mum still occupied the house.or was the bill before that an estimate,if so it could be correct.You should go and read the meter yourself,then phone them with the reading.They will send out a corrected bill.
  13. M

    BAXI Bermuda 552 tripping out

    I agree with the above posters also from my experience it sounds like the gas valve is partially choked,which would lead to the fault described and yes cancel your chimney sweep,these boilers have a metallic liner up the chimney so a sweep is completely useless.
  14. M

    HELP PLEASE ! Baumatic Oven

    The Flame supervision device is probably faulty,you`ll need to get a gas safe registered engineer to examine it and probably order and fit a part.
  15. M

    Gas cooker problem

    FSD=flame supervision device
  16. M

    Gas cooker problem

    It`s probably a faulty FSD,you`ll need to get a registered engineer in to order and fit a part.
  17. M

    Gap Appearing At Top Of Gas Fire To Wall

    It would be best to get the fire serviced this would allow an engineer to check the integrity of the fireplace,just in case there is more than a simple problem there. Do not just put a filler in as this may prevent the fire from being removed in future. Also all gas appliances should be...
  18. M

    Baumatic gas oven problem

    The FSD or thermocouple is most likely to blame,you`ll need to get a GSR engineer to fix it.
  19. M

    Back Boiler Gas Usage Between Hot Water and Central Heating

    It uses the same amount of gas regardless of whether you have the H/W or the C/H and H/W on.But,on most systems it will use less on H/W because it will shut off sooner due to the cylinder stat kicking in.You don`t have a cylinder stat,which is why it`s cycling on and off and using more gas...
  20. M

    cannon cooker keep trying to ignite on grill setting

    why do you need to know?
Back