Search results

  1. M

    Floor insulation

    loft type insulation is best- dense as possible (isowool?) to get 10kg/m3 + - rigid boards are less effective and more prone too transmitting sound rather than muffling it
  2. M

    Steel capping

    the clue to the subject of the post is in the OP's opening message - dunno what kind of forum it would be if we just read the title and answered without reading the body of the message
  3. M

    Trusses Being Cut? Any Advice Please?

    are you having building regs approval for the loft conversion - i ask as the structural aspect of the loft isnt the only consideration (or are you just trying to satisfy the mortgage people - are thay happy with just the structure being ok?)
  4. M

    Steel capping

    There is no zone at the bottom of the wall only in internal corners and at ceiling level @150mm from the junction
  5. M

    fixing joist to external wall

    4 x 2 floor joists won't span 3.1m without a central support to cut it down to 1.55m, noway nohow Have you thought about whatinsulation you will be putting in for the floor as your joists should be at least the same thickness to support properly
  6. M

    Do Velux windows need to be FENSA installed?

    FENSA only deal with replacement windows if you have existing veluxes that need replacing then you could use fensa registered installers as opposed to your LA but if they are new you can only use your LA anything else(. new openings for new windows, slightly enlarging exisiing openings...
  7. M

    Double-up celotex boards?

    celotex produce a 'handy guide' a5 booklet and ive quoted 90+25 out of therem - if you call them they will send you one For some reason their website only quotes for warm deck roof. A warm deckroof is good if you have difficulty getting cross ventilation - its a special TD3080Z celotex board...
  8. M

    Are Light tunnels or Light pipes effective?

    ive seen them in action in a stair landing and i was impressed by what they provided
  9. M

    Will this flat roof support a roof terrace?

    i take it you have been to the council and seen the plans for the roof which shows 6"x 2" joists @ 400mm c/c- yes? (bear in mind that the plans may not accurately portray the size of joist used on site to build the roof as builders often decide to do it a different way to what has been...
  10. M

    Trusses Being Cut? Any Advice Please?

    I wouldnt think a roofer/builder would be able to assess the structural integrity of modified roof trusses - a structural engineer is preferable the connection details are very important to its strength and builders/roofers basically just put the pre constructed roof trusses together like...
  11. M

    Double-up celotex boards?

    sounds like you have a new flat roof to insulate, am i right? - i think either of those options would do the trick - you must also allow another 50mm over the insulation for ventilation to flow through your soffit vents so your joists should be 190mm deep minimum. a better detail would be to...
  12. M

    Tiling over Cavities

    you could use an insulated closer like thermobate -rigid stuff
  13. M

    Double-up celotex boards?

    If you mean e.g if you need 100mm celotex floor insulation you could use 2 x 50mm celotex boards to = 100mm ive never encountered a reason why not - has someon said something?? :shock:
  14. M

    Trusses Being Cut? Any Advice Please?

    Roof trusses are manufactured under factory conditions and designed to use the minimum timber to support the intended loads (e.g roof covering, some storage and some snow). Because they are produced in a specific way to support the design loads any modification to them needs to be carried out...
  15. M

    Insulation in extension and main roofs?

    1. about 500MM (yes half a metre!)0.25 uval 2. 250mm in crossed layers 0.16 uval 3. same as 2.
  16. M

    Footings and foundations?

    entirely dependant upon the grond conditions and the loads you are putting onto the foundation then consider access and storage on site variables galore but normally strip foundations up to a depth of 1.5-2m
  17. M

    bs5839-1 2002

    if you do buy it can i borrow it? :P
  18. M

    bs5839-1 2002

    click me this place will help you out - sorry dont know how too shorten link _______________________ moderator edited to shorten link, (click here to see how its done) but linked to site only stores it for 15 mins (thats what it says)
  19. M

    Coach Bolting spans of 6" x 2" joists - how long i

    you can reduce speech sound by adding fibreglass quilt between the ceiling joists - but footfall would require something like an independant ceiling below or adding a resiliant layer below the floor or adding extra plasterboard to the ceiling below making it denser. What are you doing for...
  20. M

    self build conservatory

    Unfortunately its not as easy as a size issue - thats only one of the considerations, several factors apply other than size e.g if it has less than 75% glazed roof or less than 50% glazed walls itll need Building regs, or if its open to the house it will need them too, or if safety glass isnt...
Back