    Boiler is on and pump running when in off mode

    Just to let you know it was a stuck Mid position valve. The valve and motor head were changed. The sticking was caused by 8 dead mice in the central heating header tank. Been there a while so the water in system was a little dirty to say the least.
  10. J

    Hallway light switches

    I have a light in lowerhall area and one at bottom of stairs and light at top of stairs. In lower hallway (A) I have a 1 gang switch and 2 gang at bottom of stairs (B). When A is on the lower hall light is on, when B is on the lower hall light is still on. Both A and B have to be off to...
  11. J

    Fan - Light unit not working

    Maybe its the remote control module? Can anyone recommend a replacement
  12. J

    Overflow pipe from tank comes into conservatory

    Just moved into a property, the hotwater tank in bathroom has an overflow pipe that runs under floorboards to external wall. However it comes into conservatory. The bath sink and toilet in bathroom have an above floorboard pipe to an internal soil pipe. Obviously I should have the overflow...
  13. J

    Boiler is on and pump running when in off mode

    Tonight I have turned boiler back down to the min position. Boiler turned off, pump ran on to clear water then stopped. The timers are in off position. I turned Hot water timer to ON and the mis position valved moved to W. I then turned it back off and it is now in Mid position. Would this...
  14. J

    Fan - Light unit not working

    Fuse ok, mains tested leaving FCU to top of light I get 100v on the live to earth and 100v on the neutral to earth. Same coming out of the remote control device to the light connections. But no where else. Noticed it is not earthed! Can I bypass the remote unit? Unit is a 105cm GFI-42-4L
  15. J

    Fan - Light unit not working

    Yes it does, I will get my fluke out to test the fused switch
  16. J

    Fan - Light unit not working

    Hi Moved into to house with a conservatory with a light and fan unit. I have a remote control all works to dim lights and change fan speed. The light unit has pull cords for fan and lights but when used the unit is still dead. I have a fused switch in conservatory with the neon lit so Im...
  17. J

    Boiler is on and pump running when in off mode

    The emergency plumber did a twist with the pliers on the valve but it did visually look stiff to me. The house was empty unused for 6 months prior to me moving in. The BG 330 does have digital display hence Glow warm model. So as the frost stat internal is set at 3 degrees my system will run...
  18. J

    Boiler is on and pump running when in off mode

    I hope not as that was changed only last week. From the original British Gas Mid position valve to a same design Drayton design.
  19. J

    Boiler is on and pump running when in off mode

    No I Dont, I have just googled one of these items and I can get one with a Pipe thermostat too recommended for garage use. Would this stop the CH from being on all the time? How would this help.. sorry for my ignorance
  20. J

    Boiler is on and pump running when in off mode

    still same today, only way I can get to stop CH is to go to boiler in garage and turn it to lowest position Summer temp position. This in turn stops boiler firing and the CH pump then stops. Outside temp was 3 degrees and now I put the heat on boiler back to 65 degrees the honeywell switch is...