    Vaillent 831 running cool

    Yes - last year, by a Vaillent engineer. Had the graphite seal replaced at the same time.
  2. B

    Vaillent 831 running cool

    Hi there. I have an 8 year old Vaillent 831 with VRC430 weather compensator, which has been running well up until this cold snap. It's been completely reliable until this summer when the main board went and was replaced. With the sudden drop of temperature this week, it became obvious...
  3. B

    Encore worktops in Cambridge

    Hi there I used Home Revolution in Newmarket in the end. Did a good job and very happy with the Encore worktops which have worn well. Barry
  4. B

    Storage heater system control

    As it is, the building is a wooden built modular type structure, so probably not as well insulated as a new brick built. The central charging controls, such as on on the dimplex site, seem to act in a similar way to weather compensation does on a gas fired system, measuring outside...
  5. B

    Storage heater system control

    I'm Treasurer for a charity run preschool which has it's own building heated with cheap electric panel heaters, fitted by the builders about 4 years ago. It's 2 large rooms, plus small office and kitchen. As you can imagine, the electricity bill is buttock clenchingly high! This is not helped...
  6. B

    Vaillant VRC 430f cycling issues - a solution?

    I think this relies on air circulating through the unit to detect the temp, so not sure it's going to work if sunk into the wall?? I have had a VRC400 and VRC430 both on a 831 boiler, and haven't had any issues after the initial set up. The system seems to work well for me. It's set to...
  7. B

    vaillant vrc400 questions

    Try this http://www.diynot.com/forums/plumbing/vaillant-weather-sensor-help.288642/#2100272 Barry
  8. B

    Vaillant Weather Sensor help

    I finally got round to finding my spare and I'm getting the same readings, so sounds like a good result! Can't remember for sure, but can you calibrate the outside temp sensor using the VRC430 if it is slightly out?
  9. B

    Vaillant Weather Sensor help

    I have a spare at home, so I'll have a look see if I can see any markings or measure the resistance
  10. B

    Encore worktops in Cambridge

    Hi there I'm trying to find someone to fit an Encore Worktop in Cambridge. Any suggestions much appreciated. Thanks, Barry
  11. B

    Vaillant vrc430, vr81, vr61

    The divertor moves straight away when the tap is opened as I remember, but the VR61 seemed to be waiting for the zone valves to close before it fired the boiler. Luckily, as I said, the floor heating seems to work fine coming on at the same time as the rads, so I'm happy with the setup.
  12. B

    Vaillant vrc430, vr81, vr61

    Since I posted last, I've had to have a bit of a rethink. I have 11 rads and about 30m2 of underfloor. While the system worked with the Vr81/61, it wasn't really suited to the combi. The lag between turning the tap on and hot water was too long, due to the system waiting for the motorised...
  13. B

    Vaillant vrc430, vr81, vr61

    The system is now up and running so I thought I should update the thread in case others search for the same query. The VR61 will work with combination boilers, as confirmed by Vaillant. The problem was with the LP/ZP setting, which is set with the install assistant. This needs to be set to...
  14. B

    Vaillant vrc430, vr81, vr61

    Good news/bad news. The heating is now working faultlessly on both zones, complete with weather compensation etc. Sadly, there is no hot water - doh! When tap is opened, the heating shuts down and the display shows there is a hot water demand, but the boiler doesn't fire. close the tap...
  15. B

    Vaillant vrc430, vr81, vr61

    Hi Joe Both zones are working ok. The VRC430 is in the hall to control the rads, the vr81 in the extension to control the UFH. Problem is, the VR81 controls heating circuit 1, rather than 2. Looking at the installer level screens shows HC1 remote control = yes HC2 remote control = no...
  16. B

    Vaillant vrc430, vr81, vr61

    I ran through the entire installation again and things seem to be working ok with everything talking to each other. As far as I know, everything was set the same? The only remaining problem showed up when trying each zone in turn. The VR81 is controlling heating circuit 1, instead of 2...
  17. B

    Vaillant vrc430, vr81, vr61

    Thanks. I'll double check I've not missed anything on the installation assistant. Just seemed strange something is calling for heat as soon as it is switched on. Also seemed strange it should instantly overheat and lock out, as surely the automatic bypass should stop this happening, even is...
  18. B

    Vaillant vrc430, vr81, vr61

    I did ask Vaillant about using the VR 61 with this specific boiler and they said it was ok. However, as I said, a quick look on here does tell you all you need to know about the reputation of them!
  19. B

    Vaillant vrc430, vr81, vr61

    I have just added underfloor heating as a second zone to an ectotec 831 boiler, but I'm having a few problems setting up the controls. Originally, the boiler was controlled by a VRC400 and this worked well. while waiting to finish off the build, the radiators and underfloor heating circuits...
  20. B

    Underfloor heating dilemma

    It's an ecotec 831 about 3 years old. Radiator circuit is controled by one 2 port valve and underfloor by a second. The underfloor mixer is john guest and works really well. eventually, it will be controlled by vaillant controls (vrc430, vr61 and vr81) but at the moment, its on 2 room...