  1. K

    flue issue

    hi all, could sombody please remind me of the distance between a combi flue terminal and an extractor fan with and without a closing grill,am sure i saw on here recently a similar Q but i cant find it,have done a search to no avail. many thanks kev.
  2. K

    Possible diverter valve problem

    have you taken the moterised head off and checked to see if the pin travels fully in and out? if not then take it off and turn the tap on or get sombody to do it whilst you watch the head,if it moves all the way in and out then its the rubber ball in the diverter valve that will be...
  3. K

    Worcester 24i not producing hot water. Argh!

    jack do the rads nearest to the boiler get hot when you run the tap?
  4. K

    Stripping out lead pipe

    hi,use a lead-lock to convert from lead to copper 23mm is prob 7/8 of an inch lead so you need a 7/8-22mm leadlock,plastic is alot easier to install however its almost twice the price of copper and the fittings are silly money,dont forget to put a drain-off in somwhere at the lowest point and...
  5. K

    HELP PLEASE!Dead boiler(Simi 90)

    i may be wrong on this,however i think the sequence of operation for sime 90 is fan/pump/ignition do you have the manual for your boiler? if so check in the fault finding charts.
  6. K

    HELP PLEASE!Dead boiler(Simi 90)

    does the fan run? no fan = no fire on this boiler so start there,and if you have a corgi mate to fit the bit then he should be able to tell you exactely what bit you need to buy for him to fit?
  7. K

    Central Heating and Combi Boiler Query

    also bear in mind that the loft would need to be floored out and a rail put around the loft opening (on the inside of the loft) safety issues?! also i with the boiler in the loft space it will take an age for hot water to reach the kitchen consider this if you have a water meter fitted as you...
  8. K

    Rules for Gas Pipe clips and spacing.

    i've switched to self tappers now as i am sick of bashing mi thumbs ! :lol: and be sure to leave the head proud so you have somwhere to hang your manometer.............
  9. K

    Potterton - symptoms of faulty diverter valve?

    hi jamie just read your post and would suggest it very unwise to post your full phone number and approx location in an open forum mate, anybody and everybody now knows that chris has responded to you and could call you impersonating him to arrange a visit to your house,not trying to frighten...
  10. K

    gas fire removal/installation

    yes it can be capped off and bricked up,CORGI MAN FOR ALL YOUR GAS-WORK! and make sure you identify the correct flue terminal if capping as capping an in use flue is highly dangerous.
  11. K

    Gas supply to fireplace

    a good clue is short cut sections of floorboard either side of the breast,if you find 1 or 2,try lifting them and look for a gaspipe.if you have cellars? the job is much easier.
  12. K

    System pumping over & noisey radiator

    your plumber should have known to leave 1 rad without a trv for by-pass purposes if your pipework does'nt have a built in by-pass,drainning down to fit them may have caused a blockage,would have been an ideal time to give the system a full flush.
  13. K

    alpha 240x no hot water?

    replaced selector switch as it was in 2 halfs inside the boiler,so now it works fine in ch mode but nothing at all happens when i ask for dhw when in ch & dhw mode,turn it to dhw only and its dead as a dodo,dhw microswitch ok but plunger not coming out to activate it, in ch & dhw mode and boiler...
  14. K

    clueless female needs help

    fitz hi, think its a yorkshire number,am rgi mate,and as clueless stated that BG will fit the part for her if she can get hold of 1 but i appreciate your concerns and you are to comment on diy gaswork being dangerous,this firm is well worth keeping the number though. cheers kev.
  15. K

    cannon gas fire ffd

    hi dave, i think they changed it to everthing is 60 secs except glass fronted fires as the glass retains the heat in the thermacouple so it takes longer to shut down . kev.
  16. K

    clueless female needs help

    hi, try this number if your struggling, ALLGAS 01924381150 ask for ellaine i use them for obscure/obselete parts,they will post it to you or tell you where you can get hold of the bit you want.
  17. K

    cannon gas fire ffd

    not plumbing /heating really but maybe of interest,been to do landlord safety cert today front and rear lounge fitted with identical cannon tacotta brass effect ilfe's, passed flue & spillage on both fires ok,however the ffd on the rear fire was just about slamming shut barley just under 180...
  18. K

    vaillant sine 18

    thanks namsag,vaillant in their infinite wisdom decided to make the wax capsule obselete so your forced to buy the whole flow switch complete with micro's up top,the origonal fault on this boiler was actually the wax capsule wich i managed to get hold of 1 my supplier had on his shelf but when i...
  19. K

    vaillant sine 18

    Gasguru thanks for reply,i assume the pin to be free as this boiler is working fine in hw mode,if i swith the left hand rocker to 0(water only) the boiler works as it should,however my probs start when in heating mode,it wont shut down even with clock/programmer turned off at the wall it still...
  20. K

    vaillant sine 18

    Gasguru hi,cheers for the info,i will look at it,great pic by the way,i take it the pin moves up and down yes? and will the boiler run with the cover off? cheers.