Search results

  1. L

    Ring main problem

    doesn't matter, it won't be a N-E fault because if it was then the RCBO would trip even if the kitchen circuit was off.
  2. L

    spurs

    the house used to have storage heaters, they are long gone but the switches to switch them on and off, and the wiring back to the D/B remain. i am aiming to get most of the house running from batteries charged by a wind turbine, solar panels, and the cheap economy 7 electricity. there is only...
  3. L

    Bored with shocks in the bath .....

    i found then all hilarious! funnily enough i was reading them whilst in the bath on my ipad (its okay, it was not plugged in and is probably below 12v) but i was laughing so hard that i dropped it into the actual water which gave me shock and and also killed it :cry: even though it is...
  4. L

    Power cut...

    i think our house was built in the 20s. its on an EX council estate and we rarely have power cuts (usually only one every couple of years) but i remember once when there was a storm, every single streetlamp that i could see went out, then they came back on, then every house i could see went...
  5. L

    running utilities to shed

    why can't i just call it a garage?
  6. L

    running utilities to shed

    it would be impossible to get a caravan there unless we use a crane. but then we risk dropping it on the house and it would draw alot of attention. how do i go about getting planning permission?
  7. L

    running utilities to shed

    we have spoken to all the neighbours and they are fine with it. because the floor of it is going to be sunk into the ground (not my idea, i am trying to convince my mum against it as it sounds like a recipe for flooding) the roof will only be a bit higher than the fence. is there not a...
  8. L

    running utilities to shed

    hi, i plan to build a shed out of brick at the end of my mums garden to live in for a while. my mum has a ginnel so i never need to disturb her. i plan to have a bathroom with shower and toilet in there and a small kitchen. i am going to need: electric water a couple of runs of CAT5 (for...
  9. L

    Tripping MCB - Upstairs Lighting

    most likely answer... mice.
  10. L

    Oh ****

    been there, done that. with screws though. took forever to clean up. by forever i mean there were screws all over the kitchen floor for about a month, getting slightly smaller each day.
  11. L

    12V - 6V DC converter

    ahh right, i'd recommend it very useful and lots of tips and tricks! http://firealarmengineers.com/forum/member.php?action=register&referrer=2308 i was going to pm you so others dont get angry with me mentioning other forums but i cant find the pm button.
  12. L

    12V - 6V DC converter

    i'll probably get shot down for mentioning other forums but are you a member f the fire alarm engineeres forum?
  13. L

    12V - 6V DC converter

    http://www.ebay.co.uk/itm/Toy-car-power-converters-12V-6V-7A-42W-DC-DC-power-converters-/180723721489?pt=UK_CarsParts_Vehicles_CarParts_SM&hash=item2a13f92511#ht_3166wt_1041
  14. L

    light flashes when OFF

    we replaced the switches and it still happens (making me think mice could be the cause) i will try the different switch combinations tomorrow.
  15. L

    light flashes when OFF

    the strange thing is that it does not always do it :?
  16. L

    light flashes when OFF

    i don't remember what normal bulbs were like. i'll swap them out with normal ones when i find a shop that sells them. i would not be surprised if there was no earth in the lighting circuit at all. our house should probably be rewired but at the moment we can not afford it.
  17. L

    light flashes when OFF

    in our ground floor hallway the lights flash when the switch is OFF. we have replaced the switch and stuff and the only reason i can think of that it's doing this is that either: mice have chewed through the cable and its shorting slightly (we did have mice about 4 years ago) electrical...
  18. L

    light flashes when OFF

    in our ground floor hallway the lights flash when the switch is OFF. we have replaced the switch and stuff and the only reason i can think of that it's doing this is that either: mice have chewed through the cable and its shorting slightly (we did have mice about 4 years ago) electrical...
  19. L

    fire detector and relay base wiring

    iknow its a bit late but... the detector has more than two pins... yes? (usually has 4. +in, +out (to next detector, -, rem led output) the +ve is the +in, the -ve is the -. when the detector goes into alarm the led on the detector lights up and +5v is supplied through the rem led output pin...
  20. L

    Fire Detector & Alarm tipping Emergency Lighting

    here you go: if you need a diagram for non maintained lights then let me know!