Search results

  1. S

    COLD RAD

    First of all, is it a new rad,and did it ever get warm?
  2. S

    Banging Ecotec pro28 - There's no *** quality anymore!!

    I guess it doesn`t happen when you turn the dhw off?
  3. S

    Upstairs radiators not heating up.

    Sounds like you`ve something blocked. Is it a sealed system(combi)? If it is i doubt you`ve any check valves in the pipework.
  4. S

    PRESSURE LOSS

    In theory, your pressure guage would rise on heating demand to such an extent that it would release it through the prv and run under 3 bar while still running. Then when cool it would drop below normal pressure. As stated before in the post, if the pressure guage doesn`t rise you`ve got a leak...
  5. S

    PRESSURE LOSS

    Certainly!
  6. S

    Upstairs radiators not heating up.

    That`s tried not tied. Been one of those days that i`m sure most of you lot have had too! :(
  7. S

    Upstairs radiators not heating up.

    Have you tried turning all the rads off down stairs and the one upstairs and tied forcing the flow to the 3 non runners? Might be something as trivial as a tired pump taking the less obstructive route to the return pipe.
  8. S

    greenstar junior gurus!

    Order it with the "rain mac upgrade" if possible? :lol:
  9. S

    PRESSURE LOSS

    The diaphragm wouldn`t work correctly if it has a hole in it. Ask your plumber if he`s so confident that this is the root of your problem he`ll do a "no fix no fee" on the repair?
  10. S

    greenstar junior gurus!

    If any water at all is entering the case the fan, when running, will attract water vapour towards it as it`s heated up inside the boiler.
  11. S

    Ideal ISAR HE30 Problems

    And keep your fingers crossed that the pcb packs in while it`s still under warranty! If it`s one of the earlier pcbs it`s gonna pack in soon if you`ve had it 4 months. That might be a record :!:
  12. S

    greenstar junior gurus!

    Fitted a junior 24 a few months back, called back for a leak on the boiler, found the prv had dislodged from the brass seating. Drained the boiler and reseated the prv (push fit type) and it did it again! I rang worcester and told them of the problem, to which their reply was "the prv is not...
  13. S

    Ideal ISAR HE30 Problems

    The bench mark is a document that the installer should have left with you. It has important information on how the boiler performed from new and that it did so within manufacturers specifications. It would have flow rates, gas rates,and more importantly his name and corgi number. If you`ve not...
  14. S

    Banging Ecotec pro28 - There's no *** quality anymore!!

    Believe it or not the pro model is the budget version of the ecotec range. Smaller dhw heat exchanger, single speed pump and they`ve even scraped that exta couple of quid back by not putting a cover flap over the controls. I`ve not had any problems with the ones i`ve fitted, only installed plus...
  15. S

    Burner pressure/Gloworm

    I know what you`re on about, it`s usually green and on the top right of the backplate. Nothing at all anywhere on this bl**dy thing! I can see where it used to be, god only knows why anyone would take off all info on a boiler :? Maybe it was to cover their tracks for fitting an under rated...
  16. S

    Burner pressure/Gloworm

    Cheers gents, i`ll give them a bell tomorrow and let them scratch their heads over it. Suppose i`m too honest, i wish i`d told her it was b***ered and sold her a new one.
  17. S

    Burner pressure/Gloworm

    Afraid it is :( Don`t want to guess.
  18. S

    PRESSURE LOSS

    Do you use the boiler to heat your water via a coil through a cylinder?
  19. S

    pipe freezing

    Easier to hire one at bansons. I loved the idea at first, thought of buying one, glad i didn`t! Hired one only once. Good bits of kit but not as useful as you first think.
  20. S

    Burner pressure/Gloworm

    Changing the gas valve on a space saver II tomorrow. It`s a honeywell V8600A 24V. Anyone happen to know the burner pressure for this as there`s no manual on site for it.
Back
Top