  1. C

    Biasi boiler only producing hot water when the heating is on

    sounds live the divertor vale (diaphram in side it )has packed in or the flow switch is packed in depending on the model of your boiler. its nothing major use a wear and tear part
  2. C

    shower over a window?

    well to be honest its not some thing id want to do, if it gets wet or the tiles start to leak it will seep cause damp down the wall an could causae a lot of damage to ceiling over time
  3. C

    Main Medway Super

    i don't think a diaphram will sort the hot water to run so hot, if the diaphram had gone it wouldn't be able to push the gas valve open to fire the multipoint up, am just wondering if its over gased or the heat exchanger is scaled up making the water heat up quicker, in my opinion id be...
  4. C

    Side flueing

    you could try plumb center or parts center there local brach to you will be in yellow pages
  5. C

    Just out of curiosity...

    sounds like a old water draw off wen it was on coal gas ????
  6. C

    Boiler and system selection

    hi mate unvented hot water on conventional boiler is grate idea plenty of stored hot water an at pressure, just remember that your plumber must have his unvented an by rites rules say you must inform your local council (altho dont actualy think anyone dos) with out seeing what size rads you...
  7. C

    Glowworm 24CI

    hi mate if the timer is internal to the boiler, then you can get a new one from heating replacement spares (h.r.p.c) or if its external timer take the model number an name off it an can get a replacement from the same place :)
  8. C

    ideal mini C 28

    as tony said mate or poss faulty thermistor stats !
  9. C

    ideal etype r980n

    hi mate i may stand corrected here but arnt them boilers tank fed? does she have a copper hot water cylinder and 2 tanks in the loft ??? if so it will be self filling
  10. C

    thermostatic radiator valves

    sorry love but honey well in my opinion are better, they use a larger pin an the glands are bigger in them, they dont tend to stick as much. altho i agree the drayton look better! but practical is better than looks !
  11. C

    patio door

    FFFFS BL**DY TPYICAL! thanks lads ! 1 last question for u will a mushroom lock fit in, its wood so i can chase i wider or deeper?
  12. C

    patio door

    any better lads? I cant find anythink on these barrel is shaw not union[/img]
  13. C

    Grundfos pump horizontal or vertical?

    i personaly lean the head just off center so the back of the bleed nut is higher, thats just though personal experiance. its easyer to bleed it up coz theres a corner at a higher point.
  14. C

    No central heating

    hi mate is the flow pipe warming up at all after the boiler kettals?or is it just holding the heat in the bolier?
  15. C

    Unable to shift lock nut for sink trap

    sounds like its jumped a thread try sum grips or a screw driver on the corner of the nut a gentaly tap it may b enuff to free it up
  16. C

    Ideal Isar HE24 Boiler

    what coulor box is round the pcb ?
  17. C

    Radiators furthest from boilers not heating up

    if the boiler is cycling like yours is, the heat exchanger is moving the water fast enuff. theres ither a block in the boiler or pipe work could b caused by sludge. thing with takeing rads off an running fresh water tho the system actually can cause more problems, specialy if you live in a...
  18. C

    IDEAL CONCORD WCF

    hi mate do u see a silver flexi pipe with 2 valves on it with a screw driver slot in it? or a handle if so turn it till gauge reads 1 bar then turn them off
  19. C

    Moving Sink

    the 2 ways u said mate or a saniflow unit witch uses a smaller bore pipe so u dont need to bury it so deep
  20. C

    Oh god someone help!! Saunier Duval f30e

    sounds like the divertor valve or flow switch mate, have to recommend a pro tho mate