  1. rh2705

    Heating but no hot water

    Thanks - I will definitely look into this!
  2. rh2705

    Heating but no hot water

    Fixed!!!! I can thoroughly recommend Wickes pipe freezing kit - worked a treat! The gate valve was clogged up with brownish residue of some sort - put a new valve in anyway - as soon as the ice plug broke down I could hear a very reassuring gluggidy glug glug glug as the supply filled up...
  3. rh2705

    Heating but no hot water

    picasso it looks as though you have nailed it! drained off a good pint or three and the water level in the small tank has remained totally static. As far as I can tell the pipe at the bottom of the CH tank goes directly to the gate valve mentioned above. I risked loosening the bottom...
  4. rh2705

    Heating but no hot water

    Many thanks for your replies so far - most appreciated! Just had a look in the loft - CH header tank is full I've left the timer on HW OVERRIDE all night (CH OFF) and hot water temp is about 20­ºC at a guess (ie - NOT HOT!) Nearest Rad to the boiler is in the bathroom and its toasting...
  5. rh2705

    Heating but no hot water

    Nope - nothing like that - coil entry and exit are straight through runs of pipe and both disappear through the floor down to the boiler.
  6. rh2705

    Heating but no hot water

    I'll check tank in the morning - yes there is a gate valve which shuts off the supply from the small CH header tank - it connects directly to the bottom tank heater coil pipe after the 2 port valve, going down into the boiler in kithchen downstairs (tank is upstairs directly above boiler in...
  7. rh2705

    Heating but no hot water

    A couple of days ago we noticed our hot water was tepid, then it just stayed cold. Timer hasn't been fiddled with by the kids and when I select override for HW the boiler kicks in sure enough but quickly shuts off again. When I feel the inlet and outlet of the tank heating coil, when I...