    Amptec 12kw boiler melted incoming cables

    no went for electric as the internal chimney liner was cracked behind fitted wardrobes and had been poisioning us for years until we re decorated and relised. tHE MCB WAS TRIPPING OUT EVERY HOUR SO IT WAS WIRED STRAIGHT INTO THE RCD then it behaved however the main cable coming into the head...
  7. M

    Amptec 12kw boiler melted incoming cables

    hi it's 80amp 30ma break had it on a 50amp mcb next to rcd however every hour it would trip any ideas
  8. M

    adt alarm

    hi its a ademco quite an old one green backlit lcd panel
  9. M

    Amptec 12kw boiler melted incoming cables

    sorry did not catch the bit about connectors, the cable comes straight out of seperate fuse box rcd straight into boiler cable is 600mm long 16mm straight into the ****y 3 terminal connector soldered onto the pcb, if i change the connector it will mean desoldering the pcb which will no doubt...
  10. M

    adt alarm

    hi does any one know why a bell sybol is flashing on my adt alarm panel, it wont set
  11. M

    Amptec 12kw boiler melted incoming cables

    mine over heated so we uupped it to 16mm arfter 3 weeks it meted and bubbled the connector. told it wont be covered as its probably wiring fault either loose wire or wrong type of electric, there engineer agreed nothing wrong with wiring and placed order for a new board. next day his supervisor...
  12. M

    High Flow Shower Waste More Than 50 Litre Per Minutes

    hi used these wastes they should do the trick http://www.ec1bathrooms.co.uk/shopscr213.html the 50 lpm version is only £70 ive adapted these before with impays wetroom gully they work great,
  13. M

    boosting my pressure

    would not be mofiifying cylinder that would still have the vessel and safety devices, i was thinking about the feed out of pump and into cylinder having a vent there instead of a vessel to absorb any water if the pump overruns or is pushing out too much, the pump comes bare so would be adding...
  14. M

    boosting my pressure

    just had a thought can i instead of using a expansion vessel, vent it via a pressure relief valve back into the cwsc, the cylinder balancing valve is preset to 3bar if i set this slightly higher it would have a head of 7 meters and would help if the pump over runs and have a larger capacity then...
  15. M

    Bath filler from thermo mixer - 15mm or 22mm?

    hi had simalair prob turned out to be the ristrictor on the thermostatic valve was set to hfae to the cold took the handle off and repositioned the cam until it worked
  16. M

    boosting my pressure

    hi mr norcon you pointed me towards pumps express for a pressure controller, theres 3 ekopress easypress and brio also theres one on machine mart which is cheaper do you know which ones best suited for me, liked ekopress as its brass body apposed to plastic, should i add a small expansion vessel...
  17. M

    boosting my pressure

    sorry to sound simple will the pump i have work and will it effect performance if positioned above or below cylinder
  18. M

    boosting my pressure

    sorry cant get my head around the neg head pump, if the feed tank is 4 meters above shower water is pushing down all the time then its going into pump if pump is below cylinder as well so outlet is pushing up all the time then the pump should always be full of water, got the bit about a vessel...
  19. M

    boosting my pressure

    sorry mr doitall did not catch that the mains will run into tank via ball cock and also supply kitchen sink with a check valve as standard, the pump will pump stored water to cylinder via a balancing valve located on cylinder, this will give pumped cold feed to cylinder and pumped cold feed to...
  20. M

    boosting my pressure

    Hi what brand did you use and what sort of pressure do you have on your mains to start with, not familair with them however am i right in saying the mains pressurisies the cylinder and the the diaphram pushes it back out, if i have say 1.5 bar during peek hours will it only pressurizes it to...
Back
Top