Search results

  1. unsafe galory

    unsafe galory

  2. superman123

    central heating problems

    go for the replacment programmer then
  3. superman123

    central heating problems

    Do you have a frost stat .ie is your boiler in the garage
  4. superman123

    Flexible hose to gas hob?

    i went to a property the other week ,to a gas leak, the leak was found on the hose caused by a rat this was easy to identify as it was behind a free standing cooker.
  5. superman123

    IDEAL ICOS HE12 BOILER - PCB ADVICE

    oops!!!! 35kw. its only an icos he12 :?
  6. superman123

    Copper Pipe in Screed

    That issssss a lot of ties.
  7. superman123

    IDEAL ICOS HE12 BOILER - PCB ADVICE

    Get the jumper links wrong you could be in trouble mate. Get a gas safe engineer to fit & look the boiler over. best to be safe!!!
  8. superman123

    Help - radiators not working since engineer came!

    you could have a blockage in the cold feed from the small tank, follow the pipe then get a magnet and put on the cold feed aprox 3 inch from where it connects to the system , if you feel resistance then thats where the blockage is. when your rads are working again check for cold spots at the...
  9. superman123

    Water Pressure Help Needed

    i would be expecting 12 to 16 LPM on mains water supply 6 would be very low. poss crushed pipe or stop valve partly shut down.
  10. superman123

    Britony Combi 100 - No Hot Water!

    time to get it serviced it could be the water throttle head dout its the 3 way valve. look up the gas safe web site there you can a qualefied engineer who will fix it and give it a long over due service, easy repair for the pro. remember a boiler needs tlc just like a car from time to time you...
  11. superman123

    Worcester greenstar 28i junior - air in pump?

    it is alegal for anyone to remove the boiler case unless you are a gas safe registered emgineer. get it checked out, see the gas safe website
  12. superman123

    Glow worm 30Cxi fluctuating bar pressure display problem

    there are issues with the internal filling system your boiler wont work below 0.5 bar. manf recamend an external filling loop should be fitted
  13. superman123

    asap please- Getting new boiler fitted

    i would pay the xtra 200 quid for the worcester greenstar 30 cdi. havent found many faults on these.good boiler. if money is tight look at the ideal iogic 30. but stay away from the vokera.
  14. superman123

    Glowworm 24cxi combi boiler fault please help!

    no you can buy the head seperately, you can do it your self if your capable I am gessing that you are a gassafe engineer. so you should understand that with all the years of training we all have & the importance to know your way around a boiler, to ensure it is safe and in good working...
  15. superman123

    Glowworm 24cxi combi boiler fault please help!

    picasso is wrong if the diverter motor is blowing the fuses the cartridge is leaking into the motor so both will need replacing also the flow sensor is natorious on these get a gassafe engineer to check for moisture on the lead. picasso shouldnt be telling un qualefied people to repair there own...
  16. superman123

    Ideal evoHE

    with the heating switched off. turn dhw on ,feal the far left pipe under boiler this is the ch flow, if it heats up then yes it will be div, check you dont have a dripping hot tap somewhere
  17. superman123

    Central Heating Pressure Rising too high

    if the pressure is below 3 bar and the prv is still leaking outside then it will require replacing. i would also have the pressure checked again on the expansion vessel, if it has lost all the pressure again then yes there is a leak and that will need replacing.
  18. superman123

    best place to advertise my hot air ventilation system.

    you would have to pay me to take it.javascript:emoticon(':wink:')
  19. superman123

    Central Heating Pressure Rising too high

    Why didnt the 2nd engineer recharge the expansion vessel & change the prv when he come to check your boiler, dont let them say you need replacement without checking it first prob needs pumping up. not for diyers though.
  20. superman123

    I dont install boilers,,i go back to fix them.so get it right 1st time

    I dont install boilers,,i go back to fix them.so get it right 1st time