  1. S

    Pressure rising in Baxi combi boiler

    sounds like an expansion problem, get your service engineer back, this should be checked at regular intervals and normally on a service. im not overly farmiliar with this paticular boiler but it could be an auto air vent leaking within the boiler(the brown stuff) needs to be checked by an rgi...
  2. S

    Bathroom suites

    seco, where do you get them smilies :lol:
  3. S

    Cloudy hot water from taps

    if the water temperature is hot enough you shouldn't need to adjust it, and the cloudiness will be air bubbles, quite normal, nothing to worry about.
  4. S

    Re-lighting Optima FF50

    an optima ff50 has a auto pilot and should light on its own as long as there is a demand, buy the fact that the boiler is making a noise there must be a demand, if this model is sparking but still has no ignition there is either a lack of gas, check to see if other gas appliances are working, if...
  5. S

    Baxi Combi Instant 105e pressure problem

    if its rising whilst heating up it will be vessel problem, if its rising continuosly especially when off on heating, it will be filling loop letting by.
  6. S

    O ring for a Carron Phoenix Jura

    best thing you can do is take a photo of the tap and get carron to identify it if it come with their sink they should be able to help, the o rings on taps are a pain, you may find the right size, its the thickness that is the problem, you will probably struugle to find one anywhere, normally...
  7. S

    Is this anaconda too much bent?

    i'm sure someone was and the post was in jest :roll:
  8. S

    Is this anaconda too much bent?

    hope the meters disced, youll have an inspector after you :shock:
  9. S

    Baxi Engineers??

    :lol:
  10. S

    Franke sink washer query

    discard the foam washer ,the one with ridges, this you use on the underside of the sink between the bottom of the bowl and the plastic strainer, i normally use a bead of white/clear silicone on the metal strainer and a bead of silicone on the top of the rubber washer and below where it meets the...
  11. S

    how to change head of plumbcenter 2-port zone-valve

    you cannot change these heads, you have to replace the entire valve.
  12. S

    Customer feeling cold

    youve found the perfect solution, scare the sh1te out of them, they will start to run and warm up in no time, cant use this method if they have no hot water though, they will want a shower after sweating, will be back on your case then :wink:
  13. S

    potterton suprima50 new pcb

    has the suprima got the manufacturers time clock in, if so you would have had to remove this as you would be aware, you may have wired the time clock incorrectly, if the system has an external programmer you will be looking at a system fault.
  14. S

    Are Wilo Pumps crap

    there you go, old wilos good, new wilos not so good :shock:
  15. S

    Are Wilo Pumps crap

    of all the wilos ive fitted not 1 runs queitly, even on new sealed systems, never had a problem with reliability though, still, have returned to using grundfos.
  16. S

    Downstairs hot water part-blockage

    1. how did grit get in when fitting the shower 2. how has it taken 5 years to arise as a problem 3. have you drained the hot water system for any reason 4. is there a shower pump on the system
  17. S

    New boiler installation

    i went to the shops the other day, bought some tuna, some cucumber, some lettuce and tomatoes, took it to the cafe down the road and asked them to make my sandwich, they kindly told me to f^*k off. think you may struggle to find someone to carry out a decent job seeing as you may be trying to...
  18. S

    Sack the plumber!

    most of us are plumbing & heating engineers, our qualifications dont quite stretch to the law of the land, try consumer rights!
  19. S

    consumer rights with new faulty Ferroli boiler

    the op has not said whether or not the installer had supplied the boiler, if the op bought the unit and the installer was just paid to install it, not necessarily his responsibility if the unit is at fault, if its been fitted as per MI's what more can he do, if the installer has been paid "fit...