  1. S

    Three Way Valve Issue ?? Am I being ripped off ??

    totally agree with tamz, PAY your installer, you sound like you want him to iron out all your problems with your heating just for changing your boiler! your installer like most of us would have assumed the bathroom rad was off of the primaries if it got hot with h/w curcuit, he has not got the...
  2. S

    oil fired boilers

    in the words of john mcenroe"you cannot be serious" :roll:
  3. S

    No hot water coming from tap. Baxi 105e combi

    have you carried out the diaphram repair yourself or did you get an engineer in? if you have no running hot water at any tap, it sounds like you or the engineer may have not turned the main water back on at the boiler isolation valve. if an engineer done the work get them back.
  4. S

    Acova towel warmer element.

    last repair i done on an acova, got the spare direct from manufacturer 01252 531207, some off these have built in remote units, right pain in the backside, pretty long winded :?
  5. S

    Vaillant Ecomax 824/2E Diverter Valve

    us in the heating industry were not numpties on the 22nd of last year when you came knocking for advice :? remember the name, next time you come for advice we will tell you to get stuft/or is that stuffed, after all we are all numpties that can't spell :(
  6. S

    Baxi Solo 3 PF50 boiler - Chattering relay fault

    Underwurlde, perhaps if you have so much experience in this field, maybe you should punt yourself around some of the leading manufacturer's and show them how to make electronic component's bulletproof. sorry forgot, you just like to waste your wealth of experience blowing your own trumpet on...
  7. S

    baxi solo 3 overheating

    Bambergas, looking at the above wording, i read it that the OP had only drained his domestics, maybe it's just me and I read it wrong, then an air lock in the heating wouldn't happen :roll:
  8. S

    Orange Staining

    is this on a shower enclosure, if so was the walls plyed, iv'e known the plywood to "bleed" through onto the grout lines, hope for your sake it isn't :cry:
  9. S

    baxi solo 3 overheating

    This should not happen, must be a wiring fault, ie pump permanently wired, be sure that is running "continuosly" and not on pump overrun, which will shut down after either a time delay or after acheiving below a certain water temperature, not 100% sure which way on this model. Fault seems...
  10. S

    Connecing a saniflow to the waste pipe.

    They are in the process of having an upstairs toilet and shower fitted. Is it possible to connect the saniflow toilet waste pipe to the waste pipe from the existing toilet? Can you buy a waste pipe with a branch to accept a saniflow input? is it just me or does anybody else f^ck these...
  11. S

    toilet cistern has small continuous run

    if thats crap i see in the bottom of the cistern, chances are there is sediment on the seat of the syphon, stopping it from seating correctly, allowing a small trickle of water to pass. try this first before any further adjustment.
  12. S

    shower pump location

    yes, you can fit at the base of the bath,(not sure about electrical regs) or above the cylinder, keep it as close to the cylinder as can be, follow ALL of the remarks Gas 4 You made, bear in mind you need a minimum flow rate to operate a standard pump, this means follows all Mi's, and clearances...
  13. S

    CH Radiator Replacement

    if you've worked out the outputs correctly, there both the same sort of output so there should not be any problems, as long as the old one gave out enough heat, the new on will have a noticable higher temperature as it has no build up of sh1t stuck to the inner surface, just remember that...
  14. S

    Central Heating System

    might of done, if he showed you how to do it with a razor sharp axe at first, if he did then it's the same guy :lol:
  15. S

    underfloor heating

    loving it mate :wink:
  16. S

    Central Heating System

    Skill saw and nail puller, watch your fingers :?
  17. S

    Two F & E Tanks in loft is this possible

    are the two F&E tanks linked. What size output is the boiler is there limited space in the loft, they may have twinned the tanks to increase the size of the expansion tank :?:
  18. S

    noisy eco tec pro 28

    Who conned you, a merchant or an installer. yes, it is far better than any diy shed boiler. has the pump been checked, there maybe excess solder or something rattling around in the pump, was the system power flushed prior to the boiler being fitted or after even :?:
  19. S

    No hot water in Kitchen Tap

    is the mixer tap a 1/4 turn type, if so it will probably be of a cartridge type, they are unfortunatly all different, you will need to know make & model of tap, or if you know the make, a picture can be forwarded to the manufacture for recognition, if you are unsure you may have to change the...