    Patio Door Frame Rotten

    Thank you Gazman 16 sorry for my slow reply, found your reply in my junk mail. When I removed the rotten wood it damaged a cement fillet directly above the damp proof course. I have removed the cement which leaves enough space to fit driveway blocks, so this is what I have done. Cemented the...
  2. Martyn Bell

    Patio Door Frame Rotten

    I have a UPVC double glazed patio door which for some strange reason has wood underneath the frame. The wood has rotten away & I have removed it, supporting the window temporarily on small blocks of wood. It has been suggested that I should replace the wood with plastic, but where can I purchase...
  3. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    I could fit it in the airing cupboard next to the programmer, but I would prefer to fit it where original is because it is in the middle of my bungalow for good reception also I would't have to fill a hole in the wall. The earth wire is effectively bare with only a short length of green/yellow...
  4. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    I am still trying to fit the new stat in the same location as the original. I need to replace the existing 3 core + earth as I can not use the earth as a live. Where can I get 4 core cable bearing in mind that it has to run through the loft space. Guess it must be cable not flex. Boiler manual...
  5. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    The cable is not round 4 core cable, so I will replace the cable with new round 4 core cable. I can then pick up a permanent supply from terminal 1 on the Sundial Y plan 10 pin connector block which also supplies the ST6400 programmer. Thank you ounce again D_Hailsham
  6. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    If it treats a loss of power as an error & keeps searching for the receiver, I assume this will drain the batteries quickly? The green/yellow wire is currently an earth which is not needed, but as it is an earth I am reluctant to rewire it as a live. Is it ok to do that?
  7. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    Thanks D_Hailsham for getting back to me. There are 4 wires to the T6360B Red, Blue, Yellow & Green/Yellow. Yes it does say that in the manual, but the Salus RT300RF is not a programmer with a clock so I don't see why it needs a permanent connection, otherwise what will happen if there is a...
  8. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    Found a video on the Salus website that shows installation of link lead between terminals 2 & 3
  9. Martyn Bell

    Replace Honeywell T6360B with Salus RT300RF

    I would like to replace my Honeywell T6360B room thermostat with a Salus RT300RF wireless thermostat. I would like to fit the Salus thermostat inplace of the Honeywell (fitted to hall wall) in the same location. The Honeywell has a switched live to control the boiler on pin 3 yellow wire, can...