    no tempreature

    Is it a cmbi? or conventional with a cylinder in the airing cupboard?
  2. P

    where's my hot water gone?boo hoo baxi 105e

    Is this a 105 instant? If it is then this is the common problem with the diverter valve to prove what i think go and turn the instant off on the hot water thermostat. The water should then run cold for 30 sec then run hot continuously.
  3. P

    Chasing Out - HELP!!

    Ofcourse to do a proffesional job you could wrap the pipe in air felt opposed to duct tape or overflow pipe. These materials will not prevent pipe sweat in the wall. Air felt will. With regards to how mush to chase, i recommend you wrap your pipe and try them in your channel if its not deep...
  4. P

    Radiator output

    THe equation to work out a rad size is: Height of room X Width of room X Lenght of room Divided by 20. This will give you what you need in Kw. If you want to convert Kw to Btu 1kw= 3412 btu.
  5. P

    Hot Water Flow

    Nope i know what your problem is. You fitted you own bathroom and i bet you used flexi hoses. The cold will be ok as it is under mains pressure. HOwever, the hot is more than likely under gravity pressure. In short rip out the flexi and put some 15mm copper in place.
  6. P

    Power Shower

    If your not sure what i mean read the box does it say what Kw the shower is? Is it a shower in the box or a small unit with 4 pipes off it?
  7. P

    CHAFFOTEUX ET MAURY. NO HOT WATER BUT HEATING IS FINE

    On some boilers they have a water pressure switch that has a rubber diaphram in the unit. I will bet you pound to a penny it is either gone brittle or split. Hence the reason it may work sometimes but not always.
  8. P

    Power Shower

    Power shower? What a unit? Or do you mean an electric shower?
  9. P

    Advice needed for choice of new boiler

    NO NO NO NO!!! How many people live in your house? How many bathrooms have you got? 9 times out of 10 24kw is a drop in the ocean. Get yourself a 28kw Baxi Platinum. They are awesome machines. They come with a 5 year guaretee parts and labour. They are a little dearer but hey you get what you...
  10. P

    Pump/Boiler Problem

    to be honest there is usually very little you can do. I would concur with the chap that said you should add some sentinel into the system. However, if the heat exchanger is blocked up there is very little you can do. You could try powerflushing but there are no guarantees.
  11. P

    Estimate for replacement of Servowarm Supreme boiler

    Let me tell just try to clarify what are you trying to achieve? Is the boiler broken? Is the system not working? What is the situation?
  12. P

    Siting of a replacement boiler

    Let me just explain the current situation with boilers. Since april last year there was a government drive to fit only efficient appliances, whether it be a washing machine or a boiler. however, where boilers were concerned the most efficient boilers available are condensing boilers. Theses come...
  13. P

    baxi solo

    Yep i think i know this one. Cant remember the exact whereabouts on this boiler but there is a manual reset on the boiler a small red button press this in and you should get the boiler back on.
  14. P

    Need help to locate..

    Not a clue either. Did he mean LST low surface temperature radiatior?
  15. P

    Valor Visage gas fire- still won't stay lit

    Yeah i would concur with that. You see the thermacouple sits in the flame and creates a millivoltage. this then holds the magnet in the gas valve which keeps the gas ways open. If the magnet in the valve has lost its magnetism it wont keep the gasways open.
  16. P

    Valor Visage gas fire- still won't stay lit

    Is there any debris, lint or dust on the themacouple? DId the themacouple get changed?
  17. P

    Valor Visage gas fire- still won't stay lit

    Is the flame sitting on the themacouple ok?
  18. P

    Which pipe is the best

    Obviously when running any pipe from the boiler you must for the first meter run them in copper. I usually run 22mm flow and returns across the landing and tee off to rads in 15mm. Never go under 15mm it causes no end of problems. If money is a problem don't use plastic. It is expensive and i...
  19. P

    Central heating problem

    3 things cause that problem. Either a blocked cold feed, the vent pipe doesn't go 18 inch (450,,) over the tank or the pump is set to high. Firstly check your pump. if it is set too high turn it down. If this seems normal open a radiator vent and if it fails to thrash water out at you, you...
  20. P

    Noisy boiler

    First of all you need to determine what is causing this 'whistle'. Usually those sorts of noises are caused by the fan ceasing. However, if it is the system which is causing the noise yes it may pay to put some sort of inhibitor into the system. Don't feel daft for asking how you administer it...