    pipe work in roof space

    not a good idea,flexi hoses for c/h ,under that heat for that time i wouldnt use them get plastic or 10 mm if its just to feed a couple of rads
  2. B

    pipe work in roof space

    Get some speedfit pipe,and just use one big run,no fittings to worry about,then use copper when you can
  3. B

    heating flush

    John d , you sound like you have read up on a few things,your obviousley a diy nut as you say your not a plumber. I wonder what you are , lollipop lady,?
  4. B

    Baxi 105e Combi Boiler problem

    Maybe i should have added, what will that tell you,that its running to quick through the boiler,losing heat before the taps or its still cold there.no offence meant
  5. B

    ariston micro mffi

    Thanks rob,its a black round type at the back,right above the hot outlet pipe connection on the boiler.I went to get one today and (2) suppliers never had them,i got told they were £8.00 so i phoned ariston to check if they were looking for the right part and he said they were,but £8.00 for a...
  6. B

    Weekly rate

    I done a 7 rad and combi installation last week.I dont have anyone to help me , so i have to move furniture ,lift carpets etc. I look to stay the first day until ive got the upstairs rads in,got drops in,gas supply in new boiler area and dropped by metre cupboard.I hang downstairs rads and as...
  7. B

    Glow Worm ?@&*$

    I had a glowworm disaster only 2 months ago.In all the years ive installed boiler's ive never had a call at 11pm to tell me "the boiler's on fire". I live 2 minutes away so when i went all the pcb and facia had melted and so had the plastic part's inside so water luckily had put the flames out...
  8. B

    Treatment of tradesmen (or tradeswomen!)

    Hilti , no wonder your busy. I bet you people think , we need someone to mind the dog,gerbil and the mother in law for 2 weeks,as there off to spain. Then i know put a nail in that pipe again, softlad leaves the job like the beverley hillbillies,hilti while your fixing that boiler will you wipe...
  9. B

    ariston micro mffi

    Fault on ariston micro combi.It is ok on c/h but no h/w, no pump.no fan,nothing when the c/h is on h/w is coming through very lukewarm,flow switch im going back to fit,what do you think
  10. B

    Noisey Myson Apollo 50si

    of course you can & its not a bad job
  11. B

    How to install shower piping in a brick wall?

    If its tight ,use denso tape,but as chris says 22mm o/flow pipe is better and easier & cleaner
  12. B

    CH pump always on

    pump overun stat ,it should carry on when boiler shuts down,to allow excess heat to get away from boiler,but its just carrying on is it,and the boiler is cold when its happening.has it just started
  13. B

    hot water but no heating

    Have you vented rads ,make sure you keep pressure up when doing it , do it when pump is off ,so dont run boiler
  14. B

    hot water but no heating

    Is pressure up to 1 1/2
  15. B

    Potterton Performa 28i no ch

    Locrep, is the pin coming out ,when its on c.heating only,or are you pulling it out,its the c/h differential valve ,can you explain to me please
  16. B

    cold rads

    Is it a potterton mzv ,white head is it with it sealed so you cant get in, ok lad/lid
  17. B

    Which Condensing Combi (8 bed house)

    You cant really go wrong with worcester,vaillant,glowworm and potterton.Its difficult because there all merging like people slag off saunier duval but there made exactley like gloworm and vaillant except £100 -200 cheaper
  18. B

    Saunier Duval

    biasi better ? i disagree and ravenheat upto now i cant go against s/duval thema's its virtually a g/worm or valient when you compare them
  19. B

    am i correct on powerflush

    I am not sure that they do any good i feel like saying your £275 throw it down the grid ,that will do your system more good than a p/flush