  1. B

    Potterton Performa 28i no ch

    How old is it ,and if its the model i think then it will be the microswitchs has it got a lead going into the c/h valve red,white and black cable that pulls out
  2. B

    am i correct on powerflush

    thanks ben,i went to kamco to buy my first machine,im no begineer at this ben,but i feel like i am,i can never get circs clear when called to do that .
  3. B

    BIASI NOT FIRING UP!

    yet i was at one last month and he'd had 2 firms in before me 1 said pcb 2 gas valve. I went for a.p.s or fan ,cleaned tubes and venturi out,perfect now
  4. B

    heating flush

    what system is it how many rads ? size of boiler ? just a combi or big f/stander combis have a 10 lire expansion vessel ,thats for a maxium of 100 litres in the system but it will have about 30 litres in
  5. B

    am i correct on powerflush

    I would like to ask your advice please lads. Powerflushing, am i carrying it as it should be . I always try and connect at the pump valves and i use fx scalebreaker,neut crystals and add inhibator. I run it without chemical for 45 min and dump 2 times,then let it dump amd leave mcw running...
  6. B

    Boiler fires up and then goes out repeatedly

    I would just like to ask you to check the flue elbow is on right ,is it the squarish type screws down in each corner
  7. B

    Using a diverter valve to connect 2 seperate C/H systems

    I recently done a job on a church which had 15 rads and keston 55 boiler. I was asked by the architect to have the hall and the foyer and toilets kept so they could have them on seperatley if needed. I was given his method which was mindboggling he wanted valves here then there a return from...
  8. B

    Saunier Duval

    I think the saunier's over the last 2 yr have been good, the thema ive fitted 11 since start of november and for £525. I can tell the customers its a sedbuk (a) combi,and apart from the built in f/loop being slow on a couple,there great . I know there not great for the price on spares but still...
  9. B

    W.B DIVERTER 28 CDI

    Thank you lads. Tax exile, you have just hit the nail on the head, that little b....... gave me suicidal thoughts. I had everything going ok but could i get it in,"NO" .I dont know weather i should say this but i cut a couple of mil of it and it went in after a while ,but i will take another job...
  10. B

    WB Highflow 400

    Leave on h/w only and put stat on min,it will fire and then go off,then feel the pipe at the top of the valve,it should be cooler than the other 2,then select c/h and put stat right up,if the motor on the d/valve moves to c/h ,feel top pipe again if it stays cooler than other 2 pipes,its jammed...
  11. B

    W.B DIVERTER 28 CDI

    I would like to ask your advice on worcester 28 cdi diverter valve please. I was at one today and found taking it ok,but trying to get the new one to not leak ( ok a bit of water was my tears) was . ........... ....... . Is there something i dont know about these , and im missing something ...
  12. B

    WB Highflow 400

    its a pig of a job, check if its thaat or the actuator on the 400, are you intrested in how i checked the d/valve or have you done that,
  13. B

    Three-Port Valve??

    is it on the right way , i know its a daft reply but?
  14. B

    Leak from Bleed Valve

    is it the normal vent plug,chrome and pin in middle,is it the actual plug or pin leaking ,either turn both ends off get a bowl and towel,take it out and ptfe will do the job
  15. B

    Another Air in system problem

    see how you go now,keep the boiler at 3 so its not building up to the hieghest temp at the boiler ,but your rads and water will still be really hot,its just not staying on until its at its limit
  16. B

    Another Air in system problem

    turn heating off when venting rads,as its best done so its filling on gravity,not getting pushed by the pump
  17. B

    ideas for curinslight weep on inaccessible compression joint

    cant you get a screwdriver in and give it a tap with a hammer , as you say jjust a slight turn will normally do it.I have to undo loads of fittings with a screwdriver and hammer,when its impossible to get at with spanners,is it a real conex with the lugs on the nut on or smooth ,
  18. B

    Another Air in system problem

    again it sounds like pumping over into tank,turn pump down and see how you go keep boiler stat to no 3 and it shouldnt pump over
  19. B

    Potterton Suprima trips mains when pump switches on

    can you disconect the pump and see it stops
  20. B

    Potterton Suprima trips mains when pump switches on

    the pump has a ,the name of the part has gone out my head,were the wiring goes ,is the small round part with 2 rted wires from it ,i find when the pump is blowing the fuses or tripping its that