    If there is seperate flow and return pipes for up and down then it would be quite simple, you would need to fit two zone valves only on the flow pipes and possibly a bypass valve, these could then be controlled by a programmer/timer and have a room stat for up and one for down. The roomstat...
  2. C

    Removing a Hepvo trap to clear blockage

    Nope dont worry about that, the pipe goes in the trap about an inch so you'll need that much movement to pull it out.
  3. C

    Removing a Hepvo trap to clear blockage

    You'll need movement in the pipe to be able to get that out, be warned if it is backed up and you pull the pipe out of that trap water will go everywhere.
  4. C

    Central Heating Tripping Electric

    Sounds like waters dripped onto something it shouldnt.
  5. C

    Leaky pump problem - Help required

    You could try tightening the 2 allen key bolts on the pump head otherwise its new pump time. The pumps do get really hot in use anyway. Cylinder in the loft?? I think you'll find it will be a cold water storage tank or a feed and expansion tank, if its overflowing you need to get it looked at..
  6. C

    next doors boiler flue distance from my property

    Different boiler manufacturers sometimes have different measurements, but usually yes 300mm from the flue to your boundary.
  7. C

    next doors boiler flue distance from my property

    300mm from the boundary. IIRC
  8. C

    Which of these boilers would you recommend?

    The warrenty depends on if your installer is registered with the manufacturer, as for controls at the very least it will need a clock and a room stat, these can vary from £30 - £300 depending on what your having.
  9. C

    Which of these boilers would you recommend?

    Duo tec doesnt come in 30kw.
  10. C

    slowly losing pressure in central heating - bellway home

    The pressure for the radiators is not connected to the mains water pressure, if you top it up and it then drops then you either have a leak somewhere or the expanssion vessel (red one) is knackered or the prv on the heating is letting by.
  11. C

    Should I put this in Disasters? - Advice please

    I've never seen a cooker with enough of a recess to take a waste pipe...
  12. C

    Baxi duotec combi 28 he showing error e119 with pressure??

    Whats showing on the gauge after you filled it up??
  13. C

    Replaced Pump, now heating wont work at all! HELP! Its freez

    He deliberately overheated the boiler!!! :shock:
  14. C

    Plumbfix copper.

    Just a heads up, plumbfix are doing bundles of 22mm for £110 inc.
  15. C

    Gas flow rate measurement

    That would be 1" and 1/2" pipework, an 837 consumes about 3.5m3 from memory, your existing pipework wont be big enough.
  16. C

    Swimming Pool Lining Problem

    Wrong water balance usually results in the liner becoming bleached, not heard of one flaking like you describe???
  17. C

    Thermostatic Shower WTF!

    Yeah I dont think you can get a 3/4 wp elbow, will have to be a bent 3/4 female iron, well supported on some 3 x 2 or something like that..
  18. C

    Thermostatic Shower WTF!

    You may have to put some extra studs or noggins in and hold it on the pipework.. I wouldn't use flexis they often reduce the internal diameter of the pipe quite a lot which isn't good for shower performance...
  19. C

    Thermostatic Shower WTF!

    You've got to recess it INSIDE the wall...