  1. J

    IP rating for shower light

    Zone 0 Requires electrical products to low voltage (max. 12 volts) and be IPX7 (the mechanical protection is unimportant). Zone 1 Requires electrical products to be IPX4 or better, or SELV with the transformer located in zone 3 or beyond. If the fitting is 240v, a 30mA RCD must be used to...
  2. J

    SECURITY LIGHTS IN BACK GARDEN FRONT ENTRANCE NOT WORKING

    how does he know its not the fuse ? did he get up their and check for a live supply ? if its new then its probabaly the lamp... the ones u get with fittings are crap
  3. J

    Supply Voltage?

    40 Amp rated Meter and higher rated fuse is apparently a permitted thing by electricity board ... we rang up several times in the past and they said its fine ...guess its really rated higher :?
  4. J

    Power to the garage

    you could use RCD sockets yes, they are quite expensive and also the cable supplying the garage could do with RCD protection probably, and so could your house sockets ... dont know how far/expensive u want to go if u can find out cable size, and say what u plan to plug in the sockets then...
  5. J

    Smoke alarms

    supposed to have dedicated circuit now, but better fitted on lighting circuit than no smokes at all .... if u fit on lighting circuit they must have battery back-up shouldnt be on RCD side due to nuisance trips... but new regs most domestic properties will be 30mA on all circuits anyway...
  6. J

    Power to the garage

    Do you have an RCD on the sockets in your house ? If you do and the garage is fed from the socket circuit in the house, then the garage lights and sockets will be RCD protected
  7. J

    Power to the garage

    You should fuse the cable to the garage ... any idea what size the cable is ? easiest way to do this is put a fused spur connection unit which will be 13amp (can be less) but this can only be done if your cable is 2.5mm2 and if your load wont exceed 13amps
  8. J

    Picture of the week!™

    IPX4 downlight on 30mA RCD ? 1mm is not good
  9. J

    Smoke alarms

    if u call fire service then they come and install battery operated smoke detectors for free, and talk through fire escape routes, safety advice etc
  10. J

    Smoke alarms

    some do radio link now .... "Aico" is a brand name that do it http://www.aico.co.uk/smoke_160.htm http://www.aico.co.uk/smoke_radio.htm The bases are the radio part ... think its quite expensive and dont know how reliable the radio link is, since never used it
  11. J

    Toilet seat near CU

    hehe thats true
  12. J

    Toilet seat near CU

    ive also read that the disboards have to be at the 'new height' ... isnt disboard a type of switch/control ? and to me it makes sense (although my company dont do it) ...since what good is a light switch if u cant reach the MCB in the disboard thats tripped... if you have a cupboard...
  13. J

    Picture of the week!™

    holes in the enclosure (20mm or so)
  14. J

    Help needed with electrical circuits.

    http://www.amazon.co.uk/Electrical-Installations-Technical-Certificate-Book/dp/0435401998 JTL Electrical installations Book 1 is OK, easy to understand, though alot is about Health and Safety
  15. J

    Consumer Unit Trips When Cutting Cable

    your 'fuse board' most probably has an RCD as the main switch. RCDs will trip if there is a Neutral-Earth fault (you cutting cable) Turning the lighting circuit off only disconnects the live (phase) conductor. not neutral
  16. J

    C&G 2330 Practice Exams

    thanks alot fizzz, thats helpful removed my email, didnt know it was against rules :P
  17. J

    C&G 2330 Practice Exams

    i dont personally need them but someone who needs to know if he is ready for them dont really know the units, .... all exams in year oneof current C&G course that would be great if u can send some to me fizzz thanks
  18. J

    C&G 2330 Practice Exams

    Does anyone know where i can find Practice exams for the C&G 2330 (1st Year) course The exams relate to health and safety in work place and also a little technical knowledge. Any practice exams related to the subject and same difficulty region would be appreciated thanks
  19. J

    Outdoor Downlights

    or use IP rated transformers
  20. J

    crazy electrics

    if the cooker switch has 2 supplies to it, then thats quite bad .... if there is a fuse/MCB for the "Cooker" turn that off and see if the sockets work try pulling/turning off Socket circuits and see if the sockets will turn off with the cooker fuse in still two fuses supplying one point...