    easier to understand than 16th edition :P
  2. J

    College assigment help - shock from non energised circuit?

    with the EFLI, what i was getting at was what RF lighting said... the earth leakage current should just go down to earth, it shouldnt build up a voltage high enough to give an electric shock. the EFLI might have been acceptable for disconnection of the breaker in a fault, but not sufficient to...
  3. J

    College assigment help - shock from non energised circuit?

    if the CPCs become live, that makes the metal parts live too i dont think disconnecting CPCs while you work on it is the resolution, since you shouldnt be getting a shock off CPC's i think you should improve EFLI at supply earth so the potential doesnt build up, preventing electric...
  4. J

    Hole saws for spots

    hehe true not that hard to cut circle with pad saw ... but if you cant do it straight away then its a time waster to practice, like u said
  5. J

    Connection query

    i usually have a bunny visit me at easter, not seen an angel yet
  6. J

    Hole saws for spots

    we use those, but its seems a bit expensive for a diyer who is only going to use it "one off" cheaper to get out a compass and cut a hole with a pad saw ( bought for as little as £1 or maybe less )
  7. J

    Qualified electrician or can you DIY ?

    "Replacement, repair and maintenance jobs are generally not notifiable, even if carried out in a kitchen or special location or associated with a special location" http://www.odpm.gov.uk/pub/323/ApprovedDocumentPElectricalsafetydwellings2006edition_id1164323.pdf page 8 "B" you are...
  8. J

    Qualified electrician or can you DIY ?

    so its ok for him to put an electric heater or a shower of 40amps in the bathroom but not to change lights of 6amps A B and C are sperate scenarios.. its ok to add a socket, a light etc its not ok to work in special locations or special installations
  9. J

    Qualified electrician or can you DIY ?

    what does lights or sockets have to do with it ? he cant carry out electrical work in special locations
  10. J

    Qualified electrician or can you DIY ?

    DESCRIPTIONS OF WORK WHERE NO BUILDING NOTICE OR DEPOSIT OF FULL PLANS REQUIRED ......... 2. Work which - (a) is not in a kitchen, or a special location, i think a shower is in a special location.
  11. J

    Ring or Radial????

    since you think its a radial, what Amp rating is the breaker protecting the circuit ?
  12. J

    Am I being thick??

    i think it usually a poor earth that gives low voltage readings .. not sure
  13. J

    Oven on rcd or not

    as friday said..if your oven is a combination of a "Oven Switch and Socket" then it should be protected by an RCD. If the supply is feeding an oven on its own, then no RCD is needed because the general operation of the oven will often trip the RCD thats whzt the NICEIC say, which i would...
  14. J

    Annoying RCD problem - please help!!

    are you sure you moved the correct neutrals ? cant think of anything else unless youve shared neutrals between circuits, 1 on RCD side and 1 on non-RCD side... which is really not allowed
  15. J

    Ring or Radial????

    if there is 2 cables in one breaker ... then just get a continuity meter on both the lives ... if there is continuity its a ring, no continuity is 2 radials only try this when you have switched off the board at main breaker or if your supply has an isolator the size of the breaker/fuse...
  16. J

    DIY Electrical work and the law - changes to Part P

    Not much to do with Part P but it might have some relevance... Old colour cable is not allowed to be used now, only EU harmonsied colours should be used. True or False ? You can use old colours on old colour installations, aslong as its not complete rewires ? Fact not opinion...
  17. J

    200 Ohms

    "If" RCD is used to provide protection... then the "Recommended" value shouldnt be above 200ohms something like that ... dont have OSG to hand
  18. J

    pme question (now with pics)

    what isnt connected to your fuse board ? PME has the earth with it, thats why you dont have an earth rod
  19. J

    Help-What qualifications do i need

    competence comes with experience not reading from a book and answering multiple choice 7yrs is an unwritten rule ive heard
  20. J

    electric meter

    electricity board, its their property