  1. E

    how to terminate swa

    cheers for that streetlighter, i think thats the best way with the nut and bolt. will make sure everythings nice and tight
  2. E

    how to terminate swa

    Bas when writing this i didnt actually have it in my had, it was around 2 am in the morning, i will take cone to the cable and tell u what side goes where :D Regarding the banjo, the wiki from diynot only shows how to terminate the banjo on a metal backbox, im not terminating like that, u...
  3. E

    how to terminate swa

    lol ignore what i said it doesnt make sense even when u have decoded it does the tapered side go towards the end of the cable or away from it i.e if 2 is where ur placing the gland kit does it face that way or will the tapered end sit facing 1? 1---------------2 Im guessing the...
  4. E

    how to terminate swa

    i just realised why i had trouble with the cone! becos the guide on wiki that i posted recommends putting everything on i did the same so when i tried pushing the cone up i had the trouble, if i had pu everything else then the cone i think i would have been ok I guess they did say it depends...
  5. E

    how to terminate swa

    thanks for the replies guys i didnt see all of them untill now, wish i had seen them earlier but anyway i rigged up one end of the cable with he gland and what a hassle lol. The cone wouldnt go on so i used the nut to push it up and even that didnt work so i got my hammer and lightly tappe it...
  6. E

    how to terminate swa

    thanks for the replies guys, youve been more than helpful is there anything i need to know about running a copper water pipe next to the cable both will be in separate duct or conduit cheers
  7. E

    how to terminate swa

    should i just make sure to clip the swa just oustide of were i am terminating? cheers
  8. E

    how to terminate swa

    lol cheers for that bas one question i had was if your terminating insider or at a cu do you need to use the gland kit for anything other than earthing?? cheers
  9. E

    Mdpe or copper for garden tap

    I should of actually said i would prefer to use copper as im comfortable working with it and also never used mdpe before but of course your comments will be crucial on my decision I also just read that minimum depth for water is 750mm so that it shall be thank you
  10. E

    how to terminate swa

    As i am going to be doing some work with swa and was looking for some guides on terminating properly, I came across this and thought id share it with my fellow diyers http://wiki.diyfaq.org.uk/index.php?title=Terminating_SWA Maybe something like this could be put on the wiki section of...
  11. E

    Mdpe or copper for garden tap

    Hi guys Im planning to hook up a new outside garden tap at the other end of the garden, I presume 500mm below ground should be fine but i am not sure on what pipe to choose. Should I use copper or mdpe? its not a very long run, only 10-15 meters. Also if I use copper should i insulate...
  12. E

    burying cable underground

    yep b6 mcb lamps are 500w and yep am aware of part p :) edit I just realised as im going to be coming off my upstairs light radial the demand on it might be too much, is 1200w the maximum on a lighting circuit at one time? Currently there are two 500w already on this circuit which have...
  13. E

    burying cable underground

    ok guys def going for the swa and pvc conduit underground im not tryina be a tight b**tard as i blive if u do it once properly it wont come back to bite u. But i wanted conduit mainly for the future ideas but since now im going to be placing the two lights back to back then i only need one...
  14. E

    burying cable underground

    ive decided i will run normal t+e in metal conduit as I want the flexibility of upgrading wiring etc in the future http://www.tlc-direct.co.uk/Main_Index/Conduit_Steel_Index/20mm_BE_Conduit_and_Fittings/index.html any comments?
  15. E

    burying cable underground

    thank for the replies guys dont have any intention to be using it in wet areas its only a neighbour is adamant that its waterproof, but I wasnt too sure to what extent that was true. cheers for the help
  16. E

    burying cable underground

    also is normal twin and earth waterproof? As in if water goes onto it will it be unaffected? cheers
  17. E

    burying cable underground

    ahhh sorry thought i mentioned he size, its 1.5 probably running about 15 metres for a couple of 500w garden flood lights
  18. E

    burying cable underground

    cheers for that, i will just run some swa inside it then so in the future can just pull through. Also how many swa cables can i get in 20mm conduit? thank you
  19. E

    burying cable underground

    Hi guys Is it ok to run cable in this pvc conduit say 500mm under the ground http://www.screwfix.com/prods/97987/Electrical/Conduit/Rigid-Conduit/Conduit-Pack-90m-Black