Search results

  1. U

    Cpc/JB/Lights question

    Evening all. The lights in my house have been wired using the junction box method and the cpc stops at the junction box. I understand that in theory the last junction box before the light pendant is effectively the same as the loop-in ceiling rose is using that particular method ,and the cpc...
  2. U

    Accessible switch - with pics

    Is the RCD an old VO-ELCB? If so it needs to go.
  3. U

    Meter tails/ Fuse comparison

    Thanks folks. So just to clarify...even though the 16mm tails between the 100A fuse and the meter seem inadequate, as long as the tails are 25mm on the consumer side of the meter, then that's my only concern. Right?
  4. U

    Meter tails/ Fuse comparison

    When checking an installation which has 16mm incoming tails to the 100A service fuse and the same size to the meter but 25mm tails from meter to cu, which part of the tails are we concerned about when comparing to the fuse? Cheers.
  5. U

    Ring Continuity Readings

    Of course it would. Just testing :oops: . It's been a long day!!
  6. U

    Ring Continuity Readings

    Hiya folks, The highest Zs from all the sockets is 0.48 ohms (which is, quite rightly, the last socket on the spur in the attic). By my calculations max loop for a B32 mcb protected circuit, taking into account the three-quarter rule, is approx 1.12 ohm, so I’m happy with that. Have I missed...
  7. U

    Ring Continuity Readings

    Just found a very dodgy junction box I need to investigate, so I'll just have to turn everything off for a while. Will let u know the outcome.
  8. U

    Ring Continuity Readings

    Thanks for that Adam :D Wasn't meaning to be pushy. I know what you mean about suppliers :evil: !!
  9. U

    Ring Continuity Readings

    Thanks Adam, any thoughts on the readings?
  10. U

    Ring Continuity Readings

    Does anybody know when 2.5mm flat pvc/pvc t&e started to have 1.5mm cpc rather than 1.00mm? Just checking continuity on the circuits of my house and noticed that the cpc for the socket rings seems to be 1.00mm. The very small upstairs ring is 25m at most with 3 sockets, but with spur (via 13a...
  11. U

    some advice please

    Ey up! Trouble a'th'mill!!
  12. U

    some advice please

    he he...and in Barnoldswick, where I live now, there's even a rumour of electric lights before the next winter solstace! What next....the wheel?!
  13. U

    some advice please

    They also run 2330 courses at Keighley College, which is where I am...
  14. U

    Which CU?

    I find tlc-direct cheap and reliable..... http://www.tlc-direct.co.uk/Main_Index/Consumer_Units_Index/Wylex_NHRS/index.html
  15. U

    one and the same?cc

    Are you sure? :? If there was a short circuit between live and neutral on a t&e cable with, say, 2.5mm2 live/neutral and 1.5mm2 earth, then wouldn't the PSCC be larger than the PEFC because of the respective CSAs? Or am I talking b****cks? :shock:
  16. U

    Who did you have a crush on?

    Debbie Harry........goddess!! :D
  17. U

    Powering through a switch

    If you go to the reference thread at the top of the thread title page you will find some diagrams that may be of use. There's one of loop-in method via the switch about two thirds of the way down page 4. Hope this helps :D
  18. U

    Quick questions

    Thank you gents :D !
  19. U

    Powering through a switch

    Hiya Crazyk69, my fellow Lancastrian, as BAS says (about 5 times I think - why is everything repeating itself here....here....here???), there's nowt wrong with the wiring of your switch it's just another way of doing it. Have you got an approved voltage tester? If you have and are comfortable...
  20. U

    Quick questions

    When a dp switch such as this (http://www.screwfix.com/app/sfd/cat/pro.jsp?cId=A331832&ts=13540&id=53010) is being used in a dedicated enclosure as an isolator between metre and CU does it matter if the incoming tails from the metre go into the top or bottom of the enclosure or is it good...