    Worcester Bosch Wont Stay Lit

    Common fault on these is the flame sensing electrode. Will often go out of place above the burner, but as has been said, an RGIs job.
  2. N

    Potterton Netaheat Electronic

    thats why several people have died due to poor maintenace/diy on this appliance over the years :shock:
  3. N

    New boilers with permanent lives

    Give it time :wink:
  4. N

    Baxi Solo 3 Pilot solenoid

    Normally when the pilot solenoid goes on this appliance the pilot LED will light on the display but the boiler will do nothing. But change it anyway, common fault.
  5. N

    Replacing water main

    Normally if you replace all the lead in your house (and underground) the water supply company will replace all lead their side. So you'll connect to plastic. I take it your doing to water regulations. If so, they should connect free. If not they'll probably be a little length of lead left under...
  6. N

    baxi solo 15he condensing boiler problems.

    Yep very common electrode fault. Baxi are still modifying it (3rd time I think) and still getting the same fault. Also the combustion door seals have a tendency to fall apart leading the overheat stat by the fan to operate.
  7. N

    Ideal Isar HE 30

    PCB required. The display unit plugs into the pcb, if you've changed the display unit then it can only be the pcb.
  8. N

    worcester/bosch combi boiler 24cdi

    Does the hot water light come on at the front panel? If not its probably the diaphragm needs replacing.
  9. N

    Help, problem with Greenstar CDi boiler

    Wheres the boiler positioned. Garage/loft etc. could be frost protection.
  10. N

    Thorn Apollo 50/65 1986

    Could be a lot of things. Why do people expect an appliance to last forever??? 1986??
  11. N

    Baxi solo ticking/clicking

    Could also be a failing solenoid on the gas valve.
  12. N

    New Baxi boiler - constantly heating water even when off?

    Did your last boiler have a permanent live supply (for pump overrun)? Your new one dosen't need one so may have been wired incorrectly.
  13. N

    Worcester 400 combi

    The non return valves by the pumps are letting by so when the pump overrun kicks in (after hw has heated) the rads are getting hot (emptying the heatbank). Get yourself plenty of o rings for this boiler as there a pain in arse once you start to move bits around :shock:
  14. N

    Boilermate III - Hot water but NO central heating

    I expect the boiler stat is not turned up high enough. Should be on max.
  15. N

    Worcester 3.5 high flow gas boiler Fault

    If a remember rightly there are 2 overheat buttons. Remove the front cover and underneath the main control box casing (not inside the casing) the buttons are left and right. They're dark red in colour and will only move about 2mm when you push them.
  16. N

    Gas appliances that actually need servicing.

    Not even if your a landlord. A Gas safety check is all thats required. Servicing is not included in this. It all depends what you call servicing? Many defects would be picked up by the landlords check (flue/vent etc) but other checks wouldn't be done on any gas appliances.
  17. N

    Gas appliances that actually need servicing.

    Did I say they shouldn't be serviced annually? No I didn't. What I was pointing out that the REGULATIONS (i.e. the law) don't specify if and when you do.
  18. N

    Gas appliances that actually need servicing.

    At least I have one :wink: