  1. B

    baxi 80e

    I never said no water i said no hot water and aint it so easy to diagnose a fault when some one has done it for you lol
  2. B

    baxi 80e

    the problem was the domestic hot water diaphragm. pin holed. The diaphragm cost £8.50 from local boiler supplies. Heres how i did it. Turn off the 3 water valves ( cold supply, central heating in and out.)at the bottom of the boiler. switch off electrical supply. slacken the 2 screws that hold...
  3. B

    baxi 80e

    the kitchen sink is the last tap on the line and this is the main problem as i have to run upstairs to turn the sink tap on so the boiler will fire up, i can then turn it off and the boiler continues to run on 1 tap. if i put the shower on i turn the sink on for the boiler to fire up then its ok...
  4. B

    baxi 80e

    it doesnt really matter which tap i turn on but 2 have to be on this is ittermittent as its coming on with 1 tap at the moment.
  5. B

    baxi 80e

    when i turn the tap on no hot water no fire up no pump no fan, however if i open a second tap ignition and alls well . any help appreciated