  1. slapper

    new boiler on old pipes = leaks, should he have warned me?

    As said before, it was the installers naivity for not pre warning you of the possible outcome. However its not a statuary obligation
  2. slapper

    SCR problems no lights

    Is an SCR the same as a DCR or an MP3 or a DVD or an IBM ?
  3. slapper

    Old coal shed to downstairs WC

    Why women under specifically 44
  4. slapper

    TigerLoop or similar to be mounted internaly.

    Got to say that was most helpful :?, your not related to Victor Meldrew are you?
  5. slapper

    TigerLoop or similar to be mounted internaly.

    Just fit a 10mm non return valve outside and single pipe to pump...Sorted
  6. slapper

    Boiler heating hot water every 10 min

    If it cuts off after 20 seconds and then comes on after 10mins, then you've a circuitory problem on Flow/Return or a partial blocked coil on cylinder. That's why its kettling on temp over 60c
  7. slapper

    Hot water cylinder connection

    More than likely this will be ok, best to drain cylinder down, remove that blank and fit a 22mm Iso valve. Connect 22mm Copper pipe.Fill up then test with pipe into a bucket. If ok then that's suitable for your hot to pump. Don't forget to cap the other 15mm feed to shower off top of cylinder
  8. slapper

    Baxi Solo 2 RS Boiler

    Need a photo of your set up, where is the boiler in relationship to cylinder ? Is it an up and over flow and return ?, does the flow go over the top and the return underneath to the cylinder ? fotos, fotos fotos :wink:
  9. slapper

    Glugging/gurgling bath trap

    Wastepipes should be seperate to each Sanitaryware, however you might get over noise on Bath by fitting a deep seal trap about 75mm.
  10. slapper

    Stuart Turner parts

    Throw it in the skip and get yerself a Salamander, far better quality.
  11. slapper

    Bermuda Back Boiler Not Firing on Water Only Setting

    It sounds like a blocked cold feed on the return, if the boiler fires up on hot water and then reaches temperature quickly and shuts off, then that would indicate no circulation on the coil of the cylinder.......Seemples :wink:
  12. slapper

    Header tank constantly overflowing

    You sure its unvented, are you a Plumber ?
  13. slapper

    Why is my oil boiler kettling?

    Chuck the bloody thing out and fit an External Grant. Seemples
  14. slapper

    Problem Fixing Back to Wall toilet onto floor

    And then keep an eye on the ceiling below for the foreseable future :wink:
  15. slapper

    efflorescence and wet/cold bricks after boiler upgrade?

    Lazy Gasman never wiped his pipe clean after soldering(flux residue) Maybe should've speedfit, no flux residue after :wink:
  16. slapper

    Blocked heating pipes on microbore

    Youll more than likely end up with repipe I,m afraid. Only way round it
  17. slapper

    Small Amount of Mud in Water - no help from British Gas

    Also check ballvalves in tanks and cisterns, probably partially blocked aswell
  18. slapper

    Vented combination cylinders

    Newark Cylinders Notts, do bespoke Combi vented cylinders to suit your needs, give em a bell
  19. slapper

    Danesmoor 20/25 with Electro Inter B11 burner - bleed advice

    I have to add to this, what is the matter with some lazy arsed Engineers not being able to get to this sort of easy work for a whole week. 10 mins work to get a family heat and hot water. Beggers belief
  20. slapper

    supply to electric shower

    What an ungrateful Rsole :twisted: