  1. Untitled

    Untitled

  2. stuff

    stuff

  3. H

    testing pipes for flow

    put the heating on and your capped pipe will get warm due to heat transfer
  4. H

    Head of water

    the hydrostatic pressure would be the same as before as atmospheric pressure is not a factor in the equation. i think thegauge would read the same
  5. H

    Head of water

    you are talking about the difference between guage pressure and absolute pressure, you cannot defeat gravity......
  6. H

    Flue Position - House Party Wall does not match fence line

    baxi boiler with plume displacement kit (not management kit) will reduce horizontal boundary clearance to 25mm
  7. H

    HELP: Worcester 280RSF, realistic efficiency ???

    combi boiler using £150 per month in gas? i would make that a resounding yes.
  8. H

    Time for a new boiler but everyone's advice is conflicting!

    imagine a BG guy suggesting the condensate should be terminated and protected properly, how very dare he.
  9. H

    Seal or not to seal...

    you need to use intumescent silicon
  10. H

    Branching flow and return pipes from boiler

    yes, no minimum branch before T
  11. H

    New radiators in loft using microbore system

    needs piped back to before themanifolds
  12. H

    Do I need to replace all the central heating pipes?

    Cut out and repipe the manifolds, its likely to be a lump of dirt moving about. Fernox f1 and f3 cold/hot flush is as per manufacturers instructions so the bg bashers wont have any luck placing blame this time unfortunately
  13. H

    converting to s plan or y plan advice needed

    go for y plan, it willl be cheaper
  14. H

    converting to s plan or y plan advice needed

    Depends on the load, y plan for 18kw or less. Magnetic filter and flush will def be a good idea
  15. H

    Steel to copper pipe - plastic pushfit in CH system

    if its stainless steel pipes then compression fittings would be better
  16. H

    10mm to 15mm reducer elbow coupling

    cut the pipe back so a street fits?
  17. H

    Boiler issue

    if it was on at full rate for a month it would use 2 and a half grands worth of gas
  18. H

    New Boiler - No Powerflush or Magnaclean

    ask yourself if you want/wanted to pay the extra for it, nothing to do with being a bad installer or installation necessarily Agile.
  19. H

    Advantage of 10mm over 15mm plastic for CH rads?

    10mm is easier to work with, and will require less fittings as the pipe can be manipulated by hand, hence cheaper.