    Ideal Icos Boiler - No Central Heating?

    if you turn hot water on at clock and turn cylinder stat up does boiler fire ? if not u need to check that a switched live is actualy being sent by the time clock
  2. D

    Icos boiler loud thump

    still sounds to me as thou flue is only just sealing.if it continues ask your guy to check how far inner flue is going into boiler seal. the collar has a taper which if in right allows more of the inner pipe to enter .the reason its gets less when warm is probably expansion hence sealing better
  3. D

    Icos boiler loud thump

    is it just as the gas ignites if so get gas pressures checked.only thing else have known to cause this is on a vertical flue installed faulty.with ally collar upside down n after awhile u get crossover on the flue
  4. D

    Baxi combi 80e, Hot /Cold DHW and rising Pressure??

    if pressure rising and u not filling it.either fill loop is passing or plate exchanger passing from one to other.turn off cold supply to boiler if it still rises its the fill loop
  5. D

    Ideal Isar HE 24

    does it have a pipe stat fitted on the flow wired to the frost stat
  6. D

    what does this valve do??

    open briefly see if gauge moves then reshut
  7. D

    Ideal Isar HE 24

    sounds like frost protection kicking in and preheat.both as should do. fit a pre heat dis kit and try lagging boiler plus pipes better.would love to hear from ideal re problems with latest ideal isar but as usual no comments
  8. D

    baxi dhw water problem

    check sensor is auctaly attached in right place
  9. D

    Baxi Duo-Tec E119 error code

    have u reopened the flow and return valves ? try taking pressure a bit higher sometimes these pressures switches are a bit sensitive.or failing that drain boiler check for debri in the pressure switch then fill boiler again.if u are sure pressure is right short 2 connections at pressure switch...
  10. D

    Anyone got an electric (wet) boiler?

    no i agree but the price of three phase commercial is much cheaper hence often used in offices ect at commercial buildings
  11. D

    Anyone got an electric (wet) boiler?

    they do seem to be much more to run than gas.they are used mainly where gas supply is not available or commercial where 3 phase is available
  12. D

    Wheres the leak???

    when u have to repressurise the boiler where is all the trapped air?.usualy its in the nearest rad to the leak
  13. D

    test pump

    water is meant to dribble from the screw cover it is to allow you to bleed air from pump just close it when done .all pumps will have a different resistance reading expect anything in the region of 100 ohms to 200
  14. D

    New combi/boiler only providing hot water

    after checking all controls and stats are set to ask for heat and are high enough
  15. D

    New central heating - gurgling & running water noises

    do you have any old rads with pipes feeding top on one side and bottom on the other
  16. D

    Isar HE30 problems!

    shambolic i assume you work for ideal?.was hoping the isar with the new water set in was going to be a lot better but apparently not had 3 die this week any comments out of interest how you have found them
  17. D

    RF Roomstat Choice?

    cm927 doesnt come with optmi setting on
  18. D

    RF Roomstat Choice?

    honeywell everytime
  19. D

    Baxi 105e - Fault on fan or flue?

    air pressure switch
  20. D

    Ideal Icos M3080 Fault

    sorry but it can be done with a bit of patience .all the physical bits remain its just rewiring