    Baxi Combi Boiler - CH/HW mode

    bout 60 to 70 for the diverter and easy to change if you have manual and a mechanical mind.just make sure u isolate electrical supply and drain the boiler.dont need to drain system just isolate boiler not forgeting to replace any lost anti corrosion agents
  2. D

    Comission before Powerflush?

    should have a benchmark filled in gas safety sheet and minor works electrical form
  3. D

    Comission before Powerflush?

    was he called bodgit or scarper !!
  4. D

    Is this boiler any good??

    duo tec good boiler and it comes as a platinum with a 5 year warranty too if u choose.simple to work on and plenty out there
  5. D

    Baxi 105e intermittent flame (with a twist?)

    watching this one with interest. hope it is the boiler cover he taking off !!
  6. D

    Baxi 105e

    hmm have to remember that one sounds like a good educated guess
  7. D

    Combi condensing boiler - problems with dimensions??

    the duo tec good reliable boiler n simple n plenty of them out there.
  8. D

    Baxi Combi 105e Boiler Fault

    get a engineer to check or change the probe .pcb,s on the 105 pretty reliable more often than not they just need a clean and adjust esp if does not happen all the time
  9. D

    Baxi Combi 105e Boiler Fault

    almost certainly ionisation probe problem then very simple n cheap but supposed to be gas guy.could even just need adjusting n cleaning.only other thing it could poss be has anybody done electrical work recently because the boiler is polarity sensative and stops this probe from working if live n...
  10. D

    Ideal Isar M30100 boiler & hot radiators all summer!

    it does add to the bill slightly but is more of a noise nuisance if in house really kit cheap n diy to fit
  11. D

    Ideal Isar M30100 boiler & hot radiators all summer!

    it fires when the heat exchanger plate falls below a certain temp.waste of time really unless hot outlets 6 foot from boiler.new boiler has preheat disable switch on front
  12. D

    Baxi Combi 105e Boiler Fault

    then sounds like ionisation probe faulty which is faulty which again is cheap to buy butttt you are supposed to be gas reg to change!!.baisicly there is a small voltage passed through the flame to prove gas has light if this sensor is not working it will not allow boiler to continue. does gas...
  13. D

    Baxi Combi 105e Boiler Fault

    when the fault occurs check to see if after the fan starts that you get a healthy spark to ignite the gas.if not it is almost certainly the aps air pressure switch.this switch proves to the boiler that fan is running correctly
  14. D

    Baxi Combi 105e Boiler Fault

    need to know how far boiler progresses through its cycle ie pump fan ignition proof of ignition. there are many things it could be need to know what step it is failing at.random guess is airswitch these are common failing on this boiler and cost bout 15 qiud and 5 min to change
  15. D

    Ideal Isar M30100 boiler & hot radiators all summer!

    ideal do make a kit to disable this preheat function very easy to fit.
  16. D

    Baxi Combi 105e Boiler Fault

    need to know what fault code comes up ie what led is light .the user manual will explain these
  17. D

    Potterton Performa 28 - Central Heating tripping problem

    fault 4 ? what does it say in the user guide for this fault. do u mean the fourth led
  18. D

    Shower Problem

    is it a straight forward mixer or thermostatic mixer makes a difference.if its a thermostatic check the cartridge
  19. D

    Its drivng me mental !

    could be leaking in a downstairs underfloor cavity even with downstairs rad valves shut