  1. D

    Help! not got a clue.

    prv can be taken into a by law kit with pump can it not ?
  2. D

    Boiler locks out and won't restart until cool - Help Please!

    just means pump weak and with helping hand starts spinning
  3. D

    YPlan central heating wiring help needed

    ooh plenty of sparkys do it too
  4. D

    Baxi Solo 2 starting problem

    does the thermister double as flow switch ?
  5. D

    Baxi Solo 2 starting problem

    has anybody told this guy to check flow switch!! first.if you have 1 green light signal from timer there just pump needs proving for fan to start
  6. D

    YPlan central heating wiring help needed

    just follow the wiring diagram supplied with mid position for y plan excluding the pump in the wiring centre . the boiler does this for you. would be better if you went and bought some 5 core cable n much tidyer. and if u used 3 core for cylinder stat and have used earth wire make sure u...
  7. D

    Ideal Boiler - No Display

    well first thing u do is repressure boiler to 1.5 bar then check the stupidly thin plug for the diplay board has not fallen off
  8. D

    Baxi Combi Instant 80 HE

    pin should close the micro switch if not it is a weak diaphram
  9. D

    Please please help - hot water flow in combi system

    check filter on cold inlet on boiler could be starving its self then vacuming in upstairs pipes !!.hard one with out seeing it
  10. D

    Please please help - hot water flow in combi system

    check stopcock open fully may just be a lack of pressure !!
  11. D

    HELP REQ'D URGENTLY - Boiler PCB

    does the fan start up or not? if not the hall effect will never register.check fan is getting required voltage correctly ie phase and neutral if so change fan
  12. D

    Old pipework failed, whos fault ?

    please dont give in to this customer fight your corner if you warned him of this scenario you are fine.some customers are scary and you need to be firm or they try it with everyone.THEY ARE NOT ALWAYS RIGHT!!
  13. D

    Please please help - hot water flow in combi system

    nope corgiman he says he has good hot flow at kitchen tap!!
  14. D

    Baffling Thermostatic Shower Valve Problem

    does the valve have none return inserts fitted ? could be fitted wrongly.and shower could be wrongly labelled!!
  15. D

    Please please help - hot water flow in combi system

    if you have hot good flow rate at one tap on a combi it is not the boiler.check rest of house hot pipe work for blockage.isolate the cold at boiler and back fill from a cold tap to a hot tap might disturb the blockage.of course might just move it elsewher too!!
  16. D

    Central heating query

    is your hot water system on permantly.if so sounds like some rads are being used as a heat sink.is it a 4 pipe boiler or three
  17. D

    combi boiler heating water when cold taps used

    sounds like you have air in a hot water pipe somewhere or a dead leg of air that is compressing .when you turn the cold tap on you are reducing the pressure at the boiler allowing the water to back flow and fire the boiler for a short while
  18. D

    Baxi 80e problem

    .this is a over heating issue not thermistor i think. think plate exchanger blocked and boiler getting to hot the thermistor is just doing its job correctly.does it reset after 5 min?
  19. D

    OK, so Ideal combi boilers are rubbish....

    does it reset everytime
  20. D

    OK, so Ideal combi boilers are rubbish....

    and what is this error code?