    ideal isar he30 condensing combi boiler

    just check that when u have had the front disassembled u have not pulled a wire off the back of the main switch on the front.have had this happen before
  2. D

    ideal isar he30 condensing combi boiler

    yes u can still do this on the newer ones
  3. D

    Pipe banging like mad when hot water is switched on

    need a bit more info ie what type of boiler and set up.sounds like u have a open system on a combi?
  4. D

    H-2 error code with Ideal Isar HE24 boiler

    yep they certainly keep warmsure in a job lol
  5. D

    H-2 error code with Ideal Isar HE24 boiler

    ahhhhhhhhhh xxxx for brains lol got ya
  6. D

    H-2 error code with Ideal Isar HE24 boiler

    had a lot of these.it is the return thermistor bad readings or oc or short.2 min to change and cheap.should read in region of 9700 to 10300 ohms when at 25 c.waste of time changing pcb he needs a meter
  7. D

    Timeswitch or Boiler problem

    could just be a simple faulty clock
  8. D

    Timeswitch or Boiler problem

    is it a 2 channel time clock and what is the hw set on cont once twice ?.if on cont just hw up to temp n turning boiler off
  9. D

    Boiler Safety Discharge Pipe

    assuming this is a condesing combi.what about condo by product?.always the option of a by law kit and lift pump
  10. D

    Please people considering instant water heaters read this

    aaaah reading this has made me smile thought i was the only one who sufferd from there hands :lol:
  11. D

    IDEAL HE 35 2 YEARS OLD - MORE PROBLEMS.

    sounds like thermistor part no e69-342 2 min to fit
  12. D

    Baxi Combi 105 cutting out.

    does it ever need resetting on ch mode?
  13. D

    Baxi Combi 105 cutting out.

    the screw missing from the auto air vent makes no difference
  14. D

    Baxi Combi 105 cutting out.

    sounds like a dodgey flow switch if u a sparkey check inside the boiler cover should be wiring diagram.shows you were the flow switch is ( the boiler cover not combustion cover )
  15. D

    No Hot Water/Heating - Plz Help Me!

    get a gas fitter to check it out probs just thermocouple and replace wire both cheap.just need a honest plumber who doesnt see work
  16. D

    BAXI 105E PROBLEM

    do the red leds climb to the top of there range when u switch heating on ? if so it may just be the thermistor resistance is reading wrong .if so just change this is very quick and cheap to change.and sounds most likely culprit
  17. D

    Help with broken system and being lead up garden path !!

    check fill and vent are on the negative side of the pump.many are not on older systems and have to be moved when changing to a fully pumped system
  18. D

    Wireless room stat wiring

    the reciever needs live and neutral.then connect 1 and 2 from the boiler to 1 and 3 on the reciever
  19. D

    Sime friendly format 80 E

    not a bad boiler nice n simple to mend. change plate exchanger and poss diaphram in diverter valve.should take any decent plumber under a hour to do.these boilers run for years with simple maintance