  1. D

    baxi combi instant 105e no ch

    try turing hw control to a minmuim then try heating.
  2. D

    baxi combi instant 105e no ch

    have u turned the hot water control to off or low this disables the preheat!! then try your heating
  3. D

    baxi combi instant 105e no ch

    lol ok sorry just checking just some people dont realise they flow switch as well.not too sure on the instant but sounds like maybe the pcb thinks it needs to preheat the water all the time.even when its up to temp
  4. D

    orange wire on 3 port mid?

    my fault for the short correct answer sorry
  5. D

    orange wire on 3 port mid?

    yes i agree but if you read the initial post the question was will it be live when hot water on.the answer is yes unless you want to tell him no and let him find out the hard way
  6. D

    baxi combi instant 105e no ch

    its not a 105 instant is it ?
  7. D

    baxi combi instant 105e no ch

    strange one look forward to the answer to this one .when u changed the thermistors you have put them in place i hope not just left them hanging as this makes a difference
  8. D

    orange wire on 3 port mid?

    so there for it is always live when demand for boiler lol as per the statment .not only live for heating as someone said!!
  9. D

    New boiler needed: combi vs standard?

    you can do both fit a good combi and still have tanks just plumbed as a s plan .then you can have good pressure on your shower n leave the kids on the tanks lol
  10. D

    shower water running hot and cold issue, while basin is fine

    check shower is piped right cold to cold hot to hot that would give them symptoms if not check cartridge for muck
  11. D

    orange wire on 3 port mid?

    orange wire live when ever demand for the boiler to fire
  12. D

    TIME SERVED PLUMBERS any advise for a newbie!

    duo is a good boiler tell us what its doing
  13. D

    Baxi 105 HE No Heat or Hot water?

    if pump not running it sounds like your heating thermistor has gone which also doubles as your flow switch
  14. D

    Swapping a Worcester Highflow for a Baxi Duotec

    in reply to westbrom yes am a sparky.but what is the first thing any boiler engineer tuns to a multimeter!!.modern boiler is 80 electronics n 20 mechanical.most boiler breakdowns are due to bad plumbers instalation n that is a fact sorry
  15. D

    Isar HE24 Noisy????

    oh well that tells me its not darfield lol there sparkys always next day.hope it sorts for you
  16. D

    Swapping a Worcester Highflow for a Baxi Duotec

    am a breakdown engineer been off the tools for years and i agree past baxis have been very poor but they got it sorted with the duo tec.sorry but they so simple to fix n reliable.ask any big time installers aka the staywarm installers they choose duo.tec over worster or ideal everytime.
  17. D

    Isar HE24 Noisy????

    they all get inspected just they run very late behind the installers.i ment which company installed the boiler. am one of the inspectors so know it will be looked at eventualy
  18. D

    Isar HE24 Noisy????

    well rest assured it will get resolved with it being goverment work it has to be inspected and passed.was it darfield or on tap ?
  19. D

    Swapping a Worcester Highflow for a Baxi Duotec

    cant speak for the worster boiler thats up to you.but duo.tec is a cracking boiler and has proved very reliable our firm fit ten a week and we swear by them
  20. D

    Isar HE24 Noisy????

    was this a boiler fitted under the staywarm /eager grant system?.sounds like a very slight leak on the flue n air trapped in pump.amazingly some plumbers dont know how to bleed them pumps.n sorry but bad choice of boiler