    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Hes just left and....no better off. When he came it all seemed to be working ok and therefore said that inline with what the other engineers had done he was going to arrange for someone to fit the APS that apparently they didnt fit on saturday :shock: Hes said failing that then it may be...
  2. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    The thing is ive not been oppressive with it. Ive merely suggested that it may be the PCB to which theyve point blank refused it. Engineer was meant to be here at 10am...not bad, its now 1430...oh and his mobile is switched off too :o
  3. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Sooo the engineers came out again on saturday and after fiting the APS and fan low and behold there is still the same problem...the fan fault light is still on. I am NOT happyone bit and an engineer will be coming out agai today. They seem to think that 1. There is a leak in the system or...
  4. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Exactly my thoughts, its gone on far too long. He has only just diagnosed the fan problem :shock: Im with you two on the PCB front, im hoping its not the PCB now though as it will be ANOTHER wait!! The fan works fine. I myself have witnessed it turning..we will have to see what happens. A...
  5. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Another twist to the tale... The repair guy has been around...and changed the thermistors, low and behold this did not sort the problem. When we offerd him the advice that the issue may be the PCB he said 'if it were the PCB then youd get no power at all'??? Is that the case?? He has now...
  6. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    I really do appreciate all the help that everyone including ChrisR have given us. There are some truly nice people on here. Repair man is coming round' with the thermistor :shock: so lets see how he goes when i tell him i think its the PCB :roll: Will let you know how i get on.
  7. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Is this something i can check?
  8. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Did you evr ask what the problem was? How good is British Gases home care product? Cheers for that. Everyone else of the same conclusion?
  9. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    FURTHER UPDATE: Have swapped the thermistors around with no change what so ever. I do not believe it is the thermistors that are the problem. The boiler is occasionally firing up but then almost instantly goes out on other occasions it will fire up for a short time and start to heat the...
  10. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Sorry Chris, yeah i did take on board what you said about them being sensors, the brass end to them just looks sort of valve like (sorry amateur me). After reading various replies i suspected a PCB failure, i have to wait for this guy to come out and try and fit the new thermistor...pain...
  11. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Ive found them both. So all i need to do to swap them over is to disconnect the wires from each, spanner the valves off, swap them over and reconnect the wires?...
  12. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Even for someone with no boiler experience?? This is what im looking at... Any ideas??
  13. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    I was really weary when he said it was only the thermistor, it didnt sit right with the symptoms...plus he didnt want to listen. What do the thermistors look like, could i change them round myself to get the heating going. The PCB gone sounds not too far off the mark hence the continual...
  14. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Exactly my thoughts... Current stae of play is that the boiler is not firing up everytime... Occasionally it fires up and starts the CH up however after a while it goes off, in most cases it tries to fire it up again but sometimes it will actually start to flash that there is a fault with...
  15. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    I really am living up to my username here :cry:
  16. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    For some reason the bloke is taking the mickey and said hes had to order the part, the thermistor that is., even though another guy tells me these are available pretty much off the shelf... :shock: Is it right that the thermistor would stop the boiler from firing up and that it would make...
  17. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Right, ive been relieving the pressure from the system and occasionally the system is now firing up and giving us CH which is a bonus but it is more than often locking out. Will play it by ear and she how things are once the thermistor is changed. BBBrrrrrr...
  18. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Nope hot water doesnt work and it wasnt working when he left. He said it wont work until hes changed the thermistor :? Just about to leave for work. Will check the filling loop and valve outside when i get in. Hopefully that will sort it. Is the thermistor the be all and end all of these...
  19. S

    Potterton 30HE Fan/Flue fault? (Pic on Page 2)

    Any ideas on the boiler problems?