Search results

  1. E

    Protecting concrete from frost

    forgot to say it should be a C20 got a all in one ballast from builders merchants and I have already brought the mesh but its was pretty cheap!
  2. E

    Protecting concrete from frost

    thank you hotrod, I will be using hessain rolls so it should not freeze and if concrete has its own heat generated than I hope it will be ok, but the temps seem to be dropping with some overnight frost, but not seriously cold, overnights of 0 or just below next week, this weekend I may still be...
  3. E

    Protecting concrete from frost

    Yes I think that it must be stopped from freezing for sure but curing times will be longer. I will speak to my local builders merchants to see if they have hessain sheets and advice on admixtures. Thanks
  4. E

    Protecting concrete from frost

    Thanks for reply, I read from cemex website that it needs to be kept a 5C for the first 48hrs, I also see you can get frost blankets from a foam material probably too expensive or use hessain covers or Bubble wrap!
  5. E

    Protecting concrete from frost

    Hello, I have dug a trench footing for a full height conservatory and now plan to concrete it, any ideas on when is too cold for laying concrete and how to protect it from frost in case I lay it and the weather forecast is wrong. This weekend was the plan but though it should be dry the...
  6. E

    Base for a full height conservatory

    Ok I will double check the plans and can call the guy as hes quite helpful so will confirm that to me. regards
  7. E

    Base for a full height conservatory

    Also reply to hotrod I am only building a flat concrete base and the wall of about 3 bricks high and 1 wide is only an edging to contain the concrete it will have no cavity and I estimate I will only need 130 standard house bricks to build the whole wall, So i will end up with what looks like a...
  8. E

    Base for a full height conservatory

    Thanks for that, I was always a bit waery of conservatory dealers, but they have supplied me with plans for the base with exact external dimensions so as long as I build to that any errors hopefully i can contribute to them!
  9. E

    full length glass conservatory, base help PLS

    Hi , I am building base for a conservatory 3m by 4m full height, the conservatory guy said build a strip fotting 300mm by 300mm then about a wall 3 bricks high in the centre, infill with hardcore 150mm 25mm sand, then damp course, insulation and 150mm of concrete on top. On his website it...
  10. E

    Base for a full height conservatory

    Again thank you for the replies, from the table in page 36 I think I fit into 300mm wide foundations but I have dug mine about 350mm to 400mm, also I will fit a A142 mesh. The depth I will keep to at least 300mm, as the conservatory people advised this is ok and it is a full height one so I...
  11. E

    Base for a full height conservatory

    Thanks for replies I will respond to hotrod first. Yes I do want to ercet some formwork i.e heavy wooden planks, also the site is quite heavy so mixture of clay and topsoil, it has been ok to dig out so not too much clay that we cant get it off the shovel! I would say its pretty solid ground and...
  12. E

    Base for a full height conservatory

    Hello, I am in the process of building a base with a builder friend for a 4m long by 3m out full height conservatory. The plan is to build strip footing with A142 mesh 300mm by 300mm, then about a 3 brick high wall, fill the centre with 150mm hardcore, DPC, insulation and 150mm of concrete...
  13. E

    cant get 2nd flouorescent bulb to work!

    Yes that is very true, I only attempt the easy bits! And not that often! Thanks
  14. E

    cant get 2nd flouorescent bulb to work!

    The solution is FAULTY BALLAST UNIT as the one in garage works in loft but the one not working in loft does the same in garage, well done to those who guessed the correct answer. I swapped bulb and starter and still same problem! I will return to Toolstation! Many Thanks
  15. E

    cant get 2nd flouorescent bulb to work!

    Wow, I did not expect so much interest over my lighting problems! I think electronicsuk has the jist of problem as the original builders put in a 100w bulb and had 1 grey cable going to pendant with earth, neutral and live I just extended to form another one and that all worked ok at good...
  16. E

    cant get 2nd flouorescent bulb to work!

    I will put it in simple terms if i can! I had a pendant loft light which worked off a switch put in by the builders. I just added another 100w bulb from the 1st one by running a piece of cable from pendant joint. This worked fine but I just wanted to swap the 100w bulbs with flourescent...
  17. E

    cant get 2nd flouorescent bulb to work!

    Hi I had 2 x 100watt bulbs in loft that worked fine. Coming into the loft the first light goes into a pendant fitting and I wired a cable off to another as in parallel. I replaced the 2nd bulb with a fluorescent and it worked with the 100w still in place, then when I added the 2nd the 2nd one...
  18. E

    Married

    Married
Back