    PROBLEM WITH Y-PLAN SYSTEM

    permanant live and switched live crossed?
  2. B

    The Law and Gas installation.

    if the valve under the hob was off and a cap fitted above, no need to test apart from ldf on the cap for let by :wink:
  3. B

    The Law and Gas installation.

    if the hob was fitted correctly in the first place their should be isolation on it,or just beside it.
  4. B

    soldering problem

    years ago we done a school,the plumber doing the drinking fountain run used everflux :shock: when the school kids returned some had severe upset stomachs which was traced back to the drinking fountains. their are two fluxes that will deposit blue bits in pipework if not flushed immediately...
  5. B

    soldering problem

    powerfow flux does deposit bits in the pipework,you must of been very heavy handed with the application of the flux :shock: it also froths and bubbles coming out the taps.was the pipework sitting dry for a while ? if so the flux hardens and turns a greeny blue,once soldered it lays in the pipe...
  6. B

    air vent type?

    some corgi registered installers do not notify[gwn] as some believe their are data protection issues.as long as he left you some paperwork i would not worry too much :roll: as for flueless fires i have never fitted one due to the fact they are dangerous to your health :shock: bg do not install...
  7. B

    oil central heating problems

    if you need to press the red button on the burner you have a prob,how long ago was it serviced,was the pressure checked,was the nozzle changed? bit more info needed.
  8. B

    Potterton Netaheat Profile

    yes you are,it has an electronic pilot no pilot =no main burner check the above posts :lol: :lol:
  9. B

    Tool for the job

    harold wilsons=stilsons ray:lol:
  10. B

    Tool for the job

    you been raiding noahs toolbox again softus? :lol: as for harolds on a plastic nut are you sure bob?
  11. B

    one for the oilmen.

    have not been to the job yet.lockout is on burner not boiler,boiler runs fine until tempreture is reached so i would assume line and filter clear thanks.
  12. B

    one for the oilmen.

    got a phonecall today about an old oil burner,cust had ran out of oil and have had the tank refilled,since it was refilled the burner runs and fires up as soon as it reaches temp boiler locks out they reset it and it runs till it reaches temp then needs resetting and so on. boiler is approx 20...
  13. B

    System Boiler

    that is my understanding as well,cly has to meet bs1566 to comply with part l.
  14. B

    Is it really necessary to have a water tank in the loft?

    have a look at themal stores,anyone can fit them and they do not require annual maintenace,they are also more tolerant on water supply and pressure req. http://www.range-cylinders.co.uk/products/flowmax/
  15. B

    tricky pipe work

    been fitting them for a couple of years and had no bother YET,where are they available from in case i come across this prob,thanks oilman
  16. B

    tricky pipe work

    oilman wrote Warmflow combi uses a twin pump no problems with the ones i have fitted work a treat and kill gas boilers with its performance 18l a min,only downside with these boilers is the lack of controls
  17. B

    Gluing toilet to porcelain floor tiles

    if the toilet manufacturers wanted their products siliconed/gripfiled/cemented,then why do they go to the trouble of putting holes in them, for screws? :roll: or are those holes their to make the product look nice? :roll: buy a good drill bit and screw it down brass or stainless screws are best...
  18. B

    Opportunity for Input

    fitted a load of halstads years ago,still eched in my mind never fit again and have maintained that thought ever since.but as you have asked for views i would like to see a easy to fit/work/service appliance,price has to be competive.spares need to be reasonable,not that you would need too many...
  19. B

    PAPERWORK FOR A NEW GAS FIRE

    never have and never will gwn,have told corgi this and am still registered.corgi cannot afford to alienate the gas installers any more due to the possible backlash[read lack of mugs=no pension] :lol: always leave a invoice or cp1/cp12 whatever the customers preference,it is the homeowners...
  20. B

    How to solder safely INSIDE a combi boiler??

    use compression fittings,stagger the joints and it is easy.be very carefull with the blowlamp as the insulation damages very easily even with a good mat.